© 2002 British Journal of Ophthalmology
SCIENTIFIC CORRESPONDENCE
Remodelling the filtration bleb
1 Department of Ophthalmology, University Hospital of Wales, Heath Park, Cardiff CF4 4XW, UK
2 Bristol Eye Hospital, Lower Maudlin Street, Bristol BS1 2LX, UK
Correspondence to:
Correspondence to:
J E Morgan;
morganje3{at}cardiff.ac.uk
Aims: To report remodelling of enlarged dysmorphic filtration blebs with conjunctival compression sutures and autologous blood injection.
Methods: A retrospective analysis of consecutively recruited patients with enlarged and dysmorphic filtration blebs who were managed with conjunctival compression sutures and subconjunctival autologous blood injections. Under topical anaesthesia, conjunctival (8.0-9.0 Nylon or 8.0 Vicryl) compression sutures were placed either side of blebs that were not showing signs of spontaneous resolution. In each case up to 0.75 ml of autologous blood was then injected into the areas of the bleb to be flattened. Supplemental injections of autologous blood were given in clinic as required.
Results: In 11 eyes of 11 patients, conjunctival compression sutures were placed and autologous blood was injected, on average, 568 days following filtration surgery (range 412023). Supplemental autologous blood injections were required in eight patients, with three injections being given in one patient. In each case, the sutures were well tolerated and satisfactory compression of the conjunctiva was achieved. The highest intraocular pressure following injection was 25 mm Hg (mean 17.3, SD 4.2) and in none of the cases did blood enter the anterior chamber or parts of the filtration bleb bounded by the sutures.
Conclusion: Conjunctival compression sutures with autologous blood provide a simple and effective means for remodelling the filtration bleb. The procedure can be performed under topical anaesthesia and does not hinder further bleb surgery, should this be required.
Keywords: filtration bleb
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Biswas, S, Zaheer, I, Monsalve, B, Diamond, J P
(2009). Compression sutures with autologous blood injection for leaking trabeculectomy blebs. Br. J. Ophthalmol.
93: 549-550
[Full Text] -
Lloyd, M., Giegengack, M., Morrison, J. C.
(2008). Surgical Reduction of Dysesthetic Blebs. Arch Ophthalmol
126: 1759-1764
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.
