Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension
1 Augenklinik der Johannes Gutenberg-Universität Mainz/ Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany
2 Koordinierungszentrum für klinische Studien/Coordination Centre for Clinical Trials, Johannes Gutenberg-University, Mainz, Germany
Correspondence to:
Correspondence to:
PD Dr Oliver Schwenn, Universitäts-Augenklinik Mainz, Langenbeckstrasse 1, D-55131 Mainz, Germany;
Schwenn{at}augen.klinik.uni-mainz.de
Background/aim: Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open angle glaucoma (POAG) and high IOP, normal tension glaucoma (NTG), and ocular hypertension (OHT). Furthermore, the authors examined whether there were any correlations with blood pressure.
Methods: 80 subjects were divided into four groups (n=20): 20 patients each with POAG, NTG, and OHT and 20 volunteers without any ocular pathology except for cataract served as a control group.
Results: The OPA of the POAG group was not statistically significant different from the control group and from the OHT group. However, OPA was statistically significant lower (p<0.01) in the NTG group compared with all other groups. The OPA of the OHT group was slightly higher compared to the healthy volunteers (p=0.09) and to the POAG patients (p=0.09). No statistically significant correlations with blood pressure could be detected. A logistic regression model was established which identified OPA as an independent risk factor for NTG.
Conclusions: The study demonstrated a decrease in OPA of patients suffering from NTG. Thus, measuring of OPA by the SmartLens dynamic observing tonometer could be helpful in the detection of NTG patients.
Keywords: normal tension glaucoma; ocular pulse amplitude; tonometer; ocular hypertension
Abbreviations: IOP, intraocular pressure; NTG, normal tension glaucoma; OHT, ocular hypertension; OPA, ocular pulse amplitude; POAG, primary open angle glaucoma
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.