Acutance, an objective measure of retinal nerve fibre image clarity

Y F Choong1,2, F Rakebrandt1, R V North1 and J E Morgan1,2

1 Retinal Imaging Laboratory, Department of Optometry and Vision Sciences, Cardiff University, PO Box 905, Cardiff CF10, UK
2 University of Wales College of Medicine, Heath Park, Cardiff CF4 4XW, United Kingdom

Correspondence to:
Correspondence to:
Mr James E Morgan, Department of Ophthalmology, University of Wales College of Medicine Heath Park, Cardiff CF4 4XW, UK;
morganje3{at}cardiff.ac.uk

Background/aims: The interpretation of high contrast retinal nerve fibre layer (RNFL) images in glaucoma can be confounded by the presence of image blur; it can be difficult to discern diffuse axon loss in a poor quality image. One solution is to provide an objective measure of the image quality based on features in the image other than the RNFL. In this study the authors have developed an objective method to quantify the clarity of RNFL images, comparing it with a subjective image grading system.

Methods: Digitally acquired, monochrome retinal images were taken from 58 eyes (one image per eye) with a Topcon 50 IX retinal camera. Image resolution was 1320 x 1032 pixels at 8 bits per pixel. Image sharpness was subjectively graded by two masked experienced observers on a scale 1 to 5 relative to a reference set of RNFL images. Software algorithms were developed using Matlab (5.2) to calculate the acutance, an objective measure of the physical characteristics that underlie the subjective impression of sharpness in an image.

Results: Acutance values could be calculated for all the images. The Pearson correlation coefficients of the log of the acutance for each image and the subjective grades of observer 1 and observer 2 were 0.90 (p<0.001, n=58) and 0.84 (p<0.001, n=58) respectively.

Conclusions: These data suggest that acutance may provide a useful objective measure of image quality, which correlates well with the subjective impression of the digital retinal image sharpness. Objective measures of image quality should help in the discrimination of diffuse retinal nerve fibre loss from image blur in patients with diffuse glaucomatous damage.

Keywords: retinal nerve fibre layer; glaucoma; optic disc; digital imaging


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Fleming, A. D., Philip, S., Goatman, K. A., Olson, J. A., Sharp, P. F. (2006). Automated assessment of diabetic retinal image quality based on clarity and field definition.. IOVS 47: 1120-1125 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Ophthalmology Jobs

Ophthalmology Jobs