© 2003 BMJ Publishing Group
EXTENDED REPORT
Retinal thickness decreases with age: an OCT study
University of Freiburg Eye Hospital, Germany
Correspondence to:
Correspondence to:
Bijan Alamouti, Habsburgerstrasse 4 Freiburg, 79104, Germany;
alamouti{at}aug.ukl.uni-freiburg.de
Background/aim: In three dimensional optic disc tomography a reference plane is required to calculate optic disc rim or cup values. The position of the reference plane often depends on the retinal thickness at the temporal disc margin. Originally it was assumed that the retinal thickness at the temporal disc margin is independent of age. The aim of the study was to check this hypothesis using optical coherence tomography, and additionally to determine the reproducibility of OCT measurements in this area.
Methods: 100 eyes of 100 healthy volunteers were included in this study. Three OCT scans were performed on each eye. The scans were aligned vertically and placed at the temporal edge of the optic disc. For each eye, the thickness of the whole retina as well as the thickness of the retinal nerve fibre layer were calculated together with their coefficients of variation. Thereafter retinal thickness and nerve fibre layer thickness were correlated with age.
Results: The mean retinal thickness was 249 (SD 22) µm. The mean nerve fibre layer thickness was 109 (22) µm. The mean coefficients of variation were 3.5% (total retinal thickness) and 8.0% (nerve fibre layer thickness). Both the total retinal thickness and the nerve fibre layer thickness were significantly correlated with age (total retina: y = 269.5 - 0.53 x x; R2 = 0.133; p = 0.0002, nerve fibre layer: y = 126.8 - 0.44 x x; R2 = 0.094; p<0.0019.
Conclusions: Using OCT scans the total retinal thickness can be calculated with high reproducibility (coefficient of variation = 3.5%). The reproducibility of nerve fibre layer thickness measurements is clearly lower (coefficient of variation = 8.0%). Both the total retinal thickness and the nerve fibre layer thickness significantly decrease with age. This influence of the age related decrease in RNFL/retinal thickness on the reference plane, however, is negligible.
Keywords: Heidelberg retina tomograph; optical coherence tomography; retinal nerve fibre layer; retinal thickness
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Huynh, S. C., Wang, X. Y., Burlutsky, G., Rochtchina, E., Stapleton, F., Mitchell, P.
(2008). Retinal and Optic Disc Findings in Adolescence: A Population-Based OCT Study. IOVS
49: 4328-4335
[Abstract] [Full Text] -
Harwerth, R. S., Wheat, J. L., Rangaswamy, N. V.
(2008). Age-Related Losses of Retinal Ganglion Cells and Axons. IOVS
49: 4437-4443
[Abstract] [Full Text] -
Kagemann, L, Mumcuoglu, T, Wollstein, G, Bilonick, R, Ishikawa, H, Townsend, K A, Gabriele, M, Fujimoto, J G, Schuman, J S
(2008). Sources of longitudinal variability in optical coherence tomography nerve-fibre layer measurements. Br. J. Ophthalmol.
92: 806-809
[Abstract] [Full Text] -
Nolan, J. M., Stringham, J. M., Beatty, S., Snodderly, D. M.
(2008). Spatial Profile of Macular Pigment and Its Relationship to Foveal Architecture. IOVS
49: 2134-2142
[Abstract] [Full Text] -
Brusini, P.
(2007). Ageing and visual field data. Br. J. Ophthalmol.
91: 1257-1258
[Full Text] -
Liew, S H M., Gilbert, C. E, Spector, T. D, Marshall, J., Hammond, C. J
(2007). The role of heredity in determining central retinal thickness. Br. J. Ophthalmol.
91: 1143-1147
[Abstract] [Full Text] -
Savini, G., Barboni, P., Carbonelli, M., Zanini, M.
(2007). The Effect of Scan Diameter on Retinal Nerve Fiber Layer Thickness Measurement Using Stratus Optic Coherence Tomography. Arch Ophthalmol
125: 901-905
[Abstract] [Full Text] -
Harwerth, R. S., Vilupuru, A. S., Rangaswamy, N. V., Smith, E. L. III
(2007). The Relationship between Nerve Fiber Layer and Perimetry Measurements. IOVS
48: 763-773
[Abstract] [Full Text] -
Ajtony, C., Balla, Z., Somoskeoy, S., Kovacs, B.
(2007). Relationship between Visual Field Sensitivity and Retinal Nerve Fiber Layer Thickness as Measured by Optical Coherence Tomography. IOVS
48: 258-263
[Abstract] [Full Text] -
Lam, D. S. C., Leung, K. S., Mohamed, S., Chan, W.-m., Palanivelu, M. S., Cheung, C. Y. L., Li, E. Y. M., Lai, R. Y. K., Leung, C. K.-s.
(2007). Regional Variations in the Relationship between Macular Thickness Measurements and Myopia. IOVS
48: 376-382
[Abstract] [Full Text] -
Huynh, S. C., Wang, X. Y., Rochtchina, E., Crowston, J. G., Mitchell, P.
(2006). Distribution of Optic Disc Parameters Measured by OCT: Findings from a Population-Based Study of 6-Year-Old Australian Children.. IOVS
47: 3276-3285
[Abstract] [Full Text] -
Zou, H., Zhang, X., Xu, X., Yu, S.
(2006). Quantitative In Vivo Retinal Thickness Measurement in Chinese Healthy Subjects with Retinal Thickness Analyzer. IOVS
47: 341-347
[Abstract] [Full Text] -
Kim, J. W., Rizzo, J. F., Lessell, S.
(2005). Delayed Visual Decline in Patients With "Stable" Optic Neuropathy. Arch Ophthalmol
123: 785-788
[Abstract] [Full Text] -
Savini, G, Zanini, M, Carelli, V, Sadun, A A, Ross-Cisneros, F N, Barboni, P
(2005). Correlation between retinal nerve fibre layer thickness and optic nerve head size: an optical coherence tomography study. Br. J. Ophthalmol.
89: 489-492
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.