SCIENTIFIC REPORT
Reproducibility of the Heidelberg retinal flowmeter in determining low perfusion areas in peripapillary retina
1 Department of Ophthalmology, University of Cologne, Cologne, Germany
2 Departments of Ophthalmology, Physiology and Biophysics, Indiana University School of Medicine, IN, USA
3 Department of Ophthalmology, University of Indiana, Indianapolis, USA
4 Department of Ophthalmology, Aristotle University of Thessaloniki, Thessaloniki, Greece
5 Institute Center for Eye Epidemiology, Jules Stein Eye Institute, UCLA School of Medicine, Los Angeles, CA, USA
6 Creighton University, Omaha, NE, USA
Correspondence to:
Correspondence to:
Alon Harris PhD, MS
Glaucoma Research and Diagnostic Center, Indiana School of Medicine, 702 Rotary Circle, Indianapolis, IN 46202, USA; alharris{at}indiana.edu
Aim: To evaluate the interobserver variability and retest reproducibility of confocal scanning laser Doppler flowmeter in measuring capillary perfusion of the peripapillary retina.
Methods: Blood flow measurements were performed in one eye of 10 normal subjects by two investigators on two different days (visits). Five separate measurements of the peripapillary blood flow parameters were recorded by each observer at each visit. The Heidelberg retina flowmeter was used to record capillary perfusion in a 2560x640 µm area of the superotemporal peripapillary region and pixel by pixel analysis was done from an area adjacent to the optic disc, with a minimum of 1600 pixels. The percentage of pixels with less than 1 arbitrary unit of flow (no flow) and 10, 25, 50, 75, 90th percentiles of flow values was calculated. Interobserver measurements were compared by paired t test. Intraclass correlations (ICC) were used to determine the interobserver variability and retest reproducibility of the measurements. Intrasession coefficients of variations (CV) were also calculated.
Results: There were no statistically significant differences between the two observers for all measurements and between visits for the percentage of pixels with no flow. ICC was 66% (range 57.09%77.1%) for pixels with no flow. For the 10, 25, 50, 75, 90th percentiles of flow the ICC was 63.07% (53.91%77.81%), 71.3% (64.23%80.85%), 72.61% (66.02%78.96%), 65.86% (58.53%74.77%), and 60.05% (54.34%70.06%), respectively. CV was 16.59%, 11.47%, 9.32%, 9.03%, 11.58%, and 16.05% for the percentage of no flow pixels and the 10, 25, 50, 75, 90th percentiles of flow, respectively.
Conclusions: The Heidelberg retinal flowmeter allows reproducible measurements of all levels of capillary perfusion areas when pixel by pixel analysis is used.
Keywords: blood flow; Heidelberg retina flowmeter; glaucoma; laser Doppler flowmetry; neuroretinal rim
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Siesky, B, Harris, A, Cantor, L B, Kagemann, L, Weitzman, Y, McCranor, L, Marques, C, Werne, A, Stefansson, E
(2008). A comparative study of the effects of brinzolamide and dorzolamide on retinal oxygen saturation and ocular microcirculation in patients with primary open-angle glaucoma. Br. J. Ophthalmol.
92: 500-504
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.