EXTENDED REPORT
A new quality assessment parameter for optical coherence tomography
1 UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
2 Tufts-New England Medical Center, Tufts University School of Medicine, New England Eye Center, Boston, MA, USA
3 Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
Correspondence to:
Correspondence to:
Joel S Schuman
MD, UPMC Eye Center, Department of Ophthalmology, University of Pittsburgh School of Medicine, 203 Lothrop Street, Eye and Ear Institute Suite 816, Pittsburgh, PA 15213, USA; schumanjs{at}upmc.edu
Aim: To create a new, automated method of evaluating the quality of optical coherence tomography (OCT) images and to compare its image quality discriminating ability with the quality assessment parameters signal to noise ratio (SNR) and signal strength (SS).
Methods: A new OCT image quality assessment parameter, quality index (QI), was created. OCT images (linear macular scan, peripapillary circular scan, and optic nerve head scan) were analysed using the latest StratusOCT system. SNR and SS were collected for each image. QI was calculated based on image histogram information using a software program of our own design. To evaluate the performance of these parameters, the results were compared with subjective three level grading (excellent, acceptable, and poor) performed by three OCT experts.
Results: 63 images of 21 subjects (seven each for normal, early/moderate, and advanced glaucoma) were enrolled in this study. Subjects were selected in a consecutive and retrospective fashion from our OCT imaging database. There were significant differences in SNR, SS, and QI between excellent and poor images (p = 0.04, p = 0.002, and p<0.001, respectively, Wilcoxon test) and between acceptable and poor images (p = 0.02, p<0.001, and p<0.001, respectively). Only QI showed significant difference between excellent and acceptable images (p = 0.001). Areas under the receiver operating characteristics (ROC) curve for discrimination of poor from excellent/acceptable images were 0.68 (SNR), 0.89 (IQP), and 0.99 (QI).
Conclusion: A quality index such as QI may permit automated objective and quantitative assessment of OCT image quality that performs similarly to an expert human observer.
Abbreviations: AROC, areas under the ROC curve; GHT, glaucoma hemifield test; HVF, Humphrey visual field; NFL, nerve fibre layer; OCT, optical coherence tomography; ONH, optic nerve head; QI, quality index; RNFL, retinal nerve fibre layer; ROC, receiver operating characteristics; SNR, signal to noise ratio; SS, signal strength; TSR, tissue signal ratio; VA, visual acuity
Keywords: optical coherence tomography; signal to noise ratio
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Kok, P. H. B., van Dijk, H. W., van den Berg, T. J. T. P., Verbraak, F. D.
(2009). A Model for the Effect of Disturbances in the Optical Media on the OCT Image Quality. IOVS
50: 787-792
[Abstract] [Full Text] -
Smith, M, Frost, A, Graham, C M, Shaw, S
(2007). Effect of pupillary dilatation on glaucoma assessments using optical coherence tomography. Br. J. Ophthalmol.
91: 1686-1690
[Abstract] [Full Text] -
van Velthoven, M E J, van der Linden, M H, de Smet, M D, Faber, D J, Verbraak, F D
(2006). Influence of cataract on optical coherence tomography image quality and retinal thickness.. Br. J. Ophthalmol.
90: 1259-1262
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.
