British Journal of Ophthalmology 2006;90:833-835
SCIENTIFIC REPORT
Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with central corneal thickness
Department of Ophthalmology, University of Bern, Inselspital, 3010 Bern, Switzerland
Correspondence to:
Correspondence to:
Milko E Iliev Department of Ophthalmology
University of Bern, Inselspital, 3010 Bern, Switzerland; milko.iliev{at}insel.ch
Background/aims: Rebound tonometry (RT) is performed without anaesthesia with a hand held device. The primary aim was to compare RT with Goldmann applanation tonometry (GAT) and to correlate with central corneal thickness (CCT). The secondary aim was to prove tolerability and practicability of RT under "study conditions" and "routine practice conditions."
Methods: In group 1 (52 eyes/28 patients), all measurements were taken by the same physician, in the same room and order: non-contact optical pachymetry, RT, slit lamp inspection, GAT. Patients were questioned about discomfort or pain. In group 2 (49 eyes/27 patients), tonometry was performed by three other physicians during routine examinations.
Results: RT was well tolerated and safe. Intraocular pressure (IOP) ranged between 6 mm Hg and 48 mm Hg. No different trends were found between the groups. RT tended to give slightly higher readings: n = 101, mean difference 1.0 (SD 2.17) mm Hg; 84.1% of RT readings within plus or minus 3 mm Hg of GAT; 95% confidence interval in the Bland-Altman analysis 3.2 mm Hg to +5.2 mm Hg. Both RT and GAT showed a weak positive correlation with CCT (r2 0.028 and 0.025, respectively).
Conclusions: RT can be considered a reliable alternative for clinical screening and in cases where positioning of the head at the slit lamp is impossible or topical preparations are to be avoided.
Abbreviations: CCT, central corneal thickness; GAT, Goldmann applanation tonometry; IOP, intraocular pressure: RT, rebound tonometry
Keywords: rebound tonometry; applanation tonometry; intraocular pressure; central corneal thickness
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Mollan, S P, Wolffsohn, J S, Nessim, M, Laiquzzaman, M, Sivakumar, S, Hartley, S, Shah, S
(2008). Accuracy of Goldmann, ocular response analyser, Pascal and TonoPen XL tonometry in keratoconic and normal eyes. Br. J. Ophthalmol.
92: 1661-1665
[Abstract] [Full Text] -
Wells, A. P., Garway-Heath, D. F., Poostchi, A., Wong, T., Chan, K. C. Y., Sachdev, N.
(2008). Corneal Hysteresis but Not Corneal Thickness Correlates with Optic Nerve Surface Compliance in Glaucoma Patients. IOVS
49: 3262-3268
[Abstract] [Full Text] -
Cervino, A
(2006). Rebound tonometry: new opportunities and limitations of non-invasive determination of intraocular pressure.. Br. J. Ophthalmol.
90: 1444-1446
[Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.
