Opaque intraocular lens for intractable diplopia: experience and patients’ expectations and satisfaction

O H Hadid1, N K Wride1, P G Griffiths1, N P Strong1 and M P Clarke1,2

1 Department of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne, UK
2 School of Neurobiology, Neurology and Psychiatry, Faculty of Medicine, Newcastle University, Newcastle upon Tyne, UK

Correspondence to:
Mr O H Hadid, Department of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne NE1 4LP, UK; omar_hadid{at}hotmail.com

Aim: To report the authors' experience with the use of opaque intraocular lenses (IOL) in diplopia unresponsive to traditional management strategies, and to assess patients’ satisfaction and the visual function of patients following insertion of opaque IOL using the Visual Function Index (VF-14).

Settings: Royal Victoria Infirmary, Newcastle upon Tyne, UK.

Method: Data were obtained on all patients who underwent insertion of an opaque IOL at our institution between 2002 and 2006. Patients were interviewed by telephone. Any visual function impairment was assessed using the VF-14 questionnaire. Patients were also asked to score subjectively their overall satisfaction with the visual outcome after opaque IOL insertion.

Results: The authors studied 12 patients (n = 12) who had insertion of opaque IOL. All patients had constant and persistent diplopia unresponsive to other treatments acceptable to the patient. The median duration of diplopia was 5.5 years (interquartile range was 2.4–17.3 years). The postoperative VF-14 ranged from 75 to 100, and the mean VF-14 was 91 (95% CI 83–99). Three patients reported a maximum score of 100. Patient satisfaction ranged from 2 to 4, and the average was 3.4 out of 4.

Conclusions: Opaque IOL insertion is a valuable option in the management of intractable diplopia. The VF-14 revealed very little or no impairment in visual function following the procedure. All patients reported improvement in their visual function and were pleased with the final outcome.

Competing interests: None.

Ethics approval: As this study was a service evaluation, formal ethics committee approval was not required.

Patient consent: Informed consent was obtained from all patients prior to surgery emphasising the risk of delaying or missing a diagnosis of primary posterior pole pathology.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Ophthalmology Jobs

Ophthalmology Jobs