Article Text

Download PDFPDF
Comparison of corneal biomechanics after microincision lenticule extraction and small incision lenticule extraction

Abstract

Objectives To evaluate and compare the change in corneal biomechanical properties after microincision lenticule extraction (MILE) and small incision lenticule extraction (SMILE).

Methods In this prospective study, 60 eyes received MILE surgery with 2 mm opening incision, while 64 eyes received SMILE procedure with 5 mm opening incision. Corneal hysteresis (CH), corneal resistance factor (CRF) and 37 other biomechanical waveform parameters were quantitatively assessed using ocular response analyser (ORA) preoperatively and up to 6 months postoperatively. All changes were calculated as the difference between preoperative and postoperative values (Δ).

Results Both CH and CRF values decreased significantly after MILE and SMILE (p<0.001). ΔCRF (o=0.028) and ΔCRF index (ΔCRF/preoperative CRF) (p=0.043) were statistically lower for all eyes at 1-week follow-up. ΔCH index (ΔCH/preoperative CH) was statistically lower at 1-week (p=0.043) and 1-month (p=0.015) follow-ups in MILE group when compared with SMILE group. In both MILE and SMILE group, ΔCH index and ΔCRF index were positively correlated with preoperative manifest refraction spherical equivalent, residual stromal thickness (RST) index (RST/preoperative central corneal thickness) and negatively correlated with lenticule thickness (p<0.05).

Conclusions Both MILE and SMILE procedures significantly altered the biomechanical characteristics of cornea. Smaller opening incision was associated with less reduction in ORA parameters during early postoperative period.

  • Cornea
  • Treatment Surgery

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.