rss
Br J Ophthalmol 1985;69:452-458 doi:10.1136/bjo.69.6.452
  • Research Article

Histopathological findings in necropsy eyes with intraocular lenses.

Abstract

The histopathological findings in five post-mortem eyes with anterior chamber and iris fixation intraocular lenses (IOLS) are discussed. The interval between lens insertion and death ranged from 3 1/2 to 52 months. Clinically the lenses were well tolerated and the surgery was considered to be successful. In one case a vitrectomy was required. Prominent histopathological features included reduced corneal endothelium (five cases), central cornea guttata (one case), dislocation of an anterior chamber IOL (one case), abnormalities of the filtration angle (five cases), non-granulomatous iritis (two cases), and iris atrophy and erosion (five cases).

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.