rss
Br J Ophthalmol 1988;72:97-100 doi:10.1136/bjo.72.2.97
  • Research Article

On the management of retained airgun pellets: a survey of 11 orbital cases.

  1. N. A. Jacobs and
  2. L. H. Morgan
  1. Manchester Royal Eye Hospital.

      Abstract

      Relevant factors determining the management of inaccessible retained lead airgun pellets are discussed in relation to 11 orbital cases. Although the injuries were of between one month's and 26 years' standing, serum lead levels were normal at under 350 micrograms/l in all instances. This is attributable to the modern alloy composition of the ammunition in question. It is concluded that surgical intervention may be indicated only where there is a mechanical disturbance of ocular motility allied with good visual function.

      This Article

      Services

      1. Request permissions

      Responses

      1. Submit a response
      2. No responses published

      Social bookmarking

      Register for free content


      Free sample
      This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
      View free sample issue >>

      Free archive
      The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
      Register to access the free archive >>

      Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.