Br J Ophthalmol 1988;72:231-235 doi:10.1136/bjo.72.3.231
  • Research Article

Pre- and postoperative refraction after cataract extraction with implantation of standard power IOL.

  1. T Olsen
  1. Department of Ophthalmology, University of Aarhus, Aarhus Kommunehospital, Denmark.

      Abstract

      The pre- and postoperative refraction results are reported in 99 patients receiving an anterior chamber lens of standard 19.0 D power after intracapsular cataract extraction. The mean refraction after the operation was -0.76 D, SD 2.13. Apart from eight patients with suspected lenticular myopia, 5% of the patients ended up with a refraction that differed more than +/- 5D from the preoperative value. This variation was due to variation in the power of the biological lens removed at surgery, the mean value of which was 22.8 D, SD 3.3. As a measure of the aniseikonia induced at surgery, the ocular magnification was calculated to increase 2.7%, SD 4.2%, as compared with the preoperative value. The variation should be considered in the discussion of whether a preoperative biometry and calculation of appropriate IOL power are recommended or not.

      Register for free content

      The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.