rss
Br J Ophthalmol 1998;82:1112-1117 doi:10.1136/bjo.82.10.1112
  • Original Article
    • Clinical science

Laser scanning tomography of localised nerve fibre layer defects

  1. Reinhard O W Burka,
  2. Anja Tuulonenb,
  3. P Juhani Airaksinenb
  1. aDepartment of Ophthalmology, University of Heidelberg, Germany, bDepartment of Ophthalmology, University of Oulu, Finland
  1. Dr Reinhard O W Burk, Department of Ophthalmology, University of Heidelberg, Im Neuenheimer Feld 400, D-69120 Heidelberg, Germany.
  • Accepted 24 March 1998

Abstract

AIMS Retinal nerve fibre layer photography is a well established method to qualitatively document early structural changes which might be induced by primary open angle glaucoma. The aim was to analyse localised retinal nerve fibre layer (RNFL) defects in a new quantitative way with respect to surface topography, defect width, and surface reflectivity by means of the technique of confocal scanning laser tomography.

METHODS 12 eyes of 12 patients with a localised RNFL defect documented in RNFL photographs and a normal appearance of the optic disc were enrolled in the study. Using confocal laser scanning tomography (Heidelberg retina tomograph, HRT) a series of 32 optical section images from different focal planes of the retina at the site of the RNFL defects were obtained. The optical section images, the reflectivity images, and the topographic images were analysed regarding the visibility of the RNFL defects. The mean surface height and the reflectance at the sites of the RNFL damage were measured and compared with the adjacent apparently normal retina. The width of the RNFL defect at 1 mm distance from the disc border was evaluated.

RESULTS RNFL defects could be detected in nine of 12 reflectivity images (75%). Single optical section images displayed the RNFL defects in 12 of 12 eyes. The defect width ranged from 0.11 to 1.0 mm. In six of 12 eyes a surface depression (34 (SD 5) μm; range 21–47 μm) was present. The reflectance ratio ranged from 0.68 to 0.94 at the site of the RNFL defect. In eyes with a glaucomatous scotoma in a 6° grid visual field (VF), the defect width was at least 0.25 mm. Surface depression and low reflectance ratio were found irrespective of the presence of a scotoma in the 6° grid VF.

CONCLUSION The majority of localised RNFL defects can be detected in reflectivity images from laser scanning tomograms. Localised RNFL defects may be differentiated according to surface topography into those with and those without a measurable surface depression. A small but deep RNFL defect is not necessarily associated with a scotoma in routine 6° grid VF static perimetry.

Footnotes

    Register for free content


    Free trial
    Individuals may register for a free 60 day online trial to all content.

    Free archive
    The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.