Table 2

Comparative results at day 60 for 20 patients with silicone PPP on one side and PVP PPP on the other side

Silicone PPP (n=20) PVP PPP (n=20)
Subjective improvement of epiphora 13 15
Tolerance
 good 0 15
 mild 15 5
 poor 5 0
Scintigraphic patency
 improved 9 15
 unchanged 6 5
 worsened 5 0