A summary of ERG results in 17 patients with helicoidal peripapillary chorioretinal degeneration
| Patient no | Age | Scotopic b-wave (μV) | Mixed rod/cone b-wave (μV) | Flicker (μV) | Rod/cone b/a ratios |
Implicit times (ms) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Acuity | Mixed rod/cone | Scotopic | |||||||||||||
| Left eye | Right eye | b-wave | a-wave | a-wave | |||||||||||
| 1 | 29 | 20/20 | 20/15 | 230 | 316 | 90 | 2.5 | 33 | 22 | 28 | |||||
| 2 | 38 | 20/60 | 20/400 | 150 | 170 | 50 | 2.21 | 44 | 26 | 32 | |||||
| 3 | 21 | 20/20 | 20/20 | 391 | 406 | 90 | 2.3 | 34 | 23 | 28 | |||||
| 4 | 71 | CF | 20/70 | 187 | 231 | 42 | 2.3 | 46 | 30 | 35 | |||||
| 5 | 79 | 20/120 | CF | 161 | 169 | 24 | 2.35 | 48 | 32 | 35 | |||||
| 6 | 81 | 20/80 | 20/200 | 191 | 234 | 5 | 2.12 | 40 | 29 | 35 | |||||
| 7 | 55 | 20/20 | 20/20 | 291 | 281 | 86 | 3.57 | 42 | 24 | 31 | |||||
| 8 | 26 | 20/20 | 20/20 | 247 | 228 | 78 | 2.38 | 37 | 27 | 30 | |||||
| 9 | 24 | 20/20 | 20/200 | 303 | 394 | 78 | 2.02 | 36 | 25 | 30 | |||||
| 10 | 70 | 20/40 | 20/40 | 275 | 331 | 94 | 2.25 | 40 | 28 | 34 | |||||
| 11 | 46 | 20/20 | 20/20 | 309 | 268 | 75 | 1.93 | 36 | 24 | 29 | |||||
| 12 | 53 | 20/30 | 20/30 | 272 | 284 | 68 | 2.1 | 36 | 27 | 31 | |||||
| 13 | 70 | 20/120 | 20/120 | 122 | 109 | 69 | 2.8 | 38 | 29 | 31 | |||||
| 14 | 42 | 20/80 | 20/80 | 150 | 172 | 63 | 2.07 | 46 | 29 | 34 | |||||
| 15 | 29 | 20/200 | 20/200 | 231 | 250 | 11 | 1.95 | 32 | 22 | 31 | |||||
| 16 | 50 | 20/20 | 20/20 | 319 | 375 | 72 | 2.45 | 39 | 25 | 31 | |||||
| 17 | 51 | 20/20 | 20/20 | 144 | 244 | 31 | 2.1 | 40 | 24 | 30 | |||||
| Patient mean | 233 | 262 | 60 | 2.33 | 39.2 | 24 | 29 | ||||||||
| SD | 76 | 83 | 28 | 0.38 | 4.72 | 2.71 | 1.41 | ||||||||
| Normal range (μV) | 200–456 | 340–680 | 82–125 | 2.05–2.75 | |||||||||||
| Normal mean (μV) | 342 | 437 | 98 | 2.33 | 39 | 22.9 | 2.8 | ||||||||
| SD | 69 | 97 | 13 | 0.22 | 4.6 | 0.87 | 1.3 | ||||||||
-
↵The flicker response was evoked with a repetition rate of 31 Hz at maximum intensity (−0.19 log cd.s/m2), the scotopic b-wave at the maximum intensity used for eliciting rod responses (−1.22 log cd.s/m2), and the mixed rod-cone b-wave at −0.27 log cd.s/m2 intensity.