rss
Br J Ophthalmol 82:534-537 doi:10.1136/bjo.82.5.534
  • Original Article
    • Clinical science

Impaired motion sensitivity as a predictor of subsequent field loss in glaucoma suspects: the Roscommon Glaucoma Study

Table 4

Independent predictor of visual field loss (95% confidence interval (CI)), using Cox proportional hazards regression analysis

Motion
impariment
Visual
field loss
(n=18)
Rate ratio
(95% CI)
Rate ratio
adjusted for age
(95% CI)
Rate ratio
adjusted age,
IOP and C/D
(95% CI)
No (>85%) 4 1.0 1.0 1.0
Yes (⩽85) 14 8.36  (2.75 to 25.4) 6.31  (1.88 to 21.68) 4.11  (1.26 to 13.5)

This Article

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
View free sample issue >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.