rss
Br J Ophthalmol 1999;83:81-84 doi:10.1136/bjo.83.1.81
  • Original Article
    • Clinical science

A single technique to correct various degrees of upper lid retraction in patients with Graves’ orbitopathy

  1. Maarten Ph Mourits,
  2. Inna Vladimirovna Sasim
  1. Orbital Center Utrecht, Donders Institute for Ophthalmology, University Hospital Utrecht, Heidelberglaan, 3584 CX Utrecht, Netherlands
  1. Dr Mourits.
  • Accepted 30 July 1998

Abstract

BACKGROUND Several lengthening techniques have been proposed for upper eyelid retraction in patients with Graves’ orbitopathy and variable rates of success have been reported. Most authors recommend different procedures for different degrees of retraction, but cannot prevent residual temporal retraction in a significant number of cases. The modified levator aponeurosis recession described by Harvey and colleagues, in which the lateral horn is cut completely, seems to be an exception to this rule, but was evaluated in a limited number of cases only.

METHOD The authors further modified Harvey’s technique by dissecting the aponeurosis together with Müller’s muscle of the tarsus and the conjunctiva medially only to the extent necessary to achieve an acceptable position and contour of the eyelid in upright position. They also used an Ethilon 6.0 suture, instead of Vicryl, on a loop. It is placed between the tarsal plate and the detached aponeurosis to prevent spontaneous disinsertion. This modification was used in 50 Graves’ patients (78 eyelids) with a upper lid margin-limbus distance ranging from 1 to 7 mm and evaluated using strict criteria.

RESULTS A perfect or acceptable result was obtained in 23 of 28 patients (82%) with bilateral retraction and in 18 of 22 patients (82%) with unilateral retraction. Seven eyelids were overcorrected (too low) and three undercorrected, necessitating reoperation. All other eyelids had an almond-like contour and a lid crease of 10 mm or less. No complications except subcutaneous haematomas were seen. Two patients showed a recurrence of lid retraction 9 months after the operation.

CONCLUSION This technique is safe and efficacious and can be used for all degrees of eyelid retraction.

Footnotes

    This Article

    Services

    1. Request permissions

    Responses

    1. Submit a response
    2. No responses published

    Social bookmarking

    Register for free content


    Free sample
    This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
    View free sample issue >>

    Free archive
    The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
    Register to access the free archive >>

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.