rss
Br J Ophthalmol 84:1142-1146 doi:10.1136/bjo.84.10.1142
  • Original Article
    • Clinical science

Ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by Soemmering's ring

Table 1

Dimensions (SD) of anterior segment before and after resolution

Before resolution After resolution p Value
Anterior chamber depth (mm) 1192 (25) 2796 (25) <0.0001
 Range 1169 to 1219 2769 to 2819
Trabecular-iris angle (degree) 0.84 (1.47) 43.30 (7.38) <0.0001
 Range 0 to 3.44 32.11 to 52.34
AOD250 (μm) 2 (6) 253 (51) <0.0001
 Range 0 to 13 188 to 312
AOD500 (μm) 13 (13) 429 (31) <0.0001
 Range 0 to 31 381 to 463
Trabecular-ciliary process distance (μm) 567 (195) 1430 (160) <0.0001
 Range 431 to 902 1144 to 1506
Iris-ciliary process distance (μm) 157 (53) 506 (156) <0.0001
 Range 94 to 203 381 to 762
Iris-zonule distance (μm) 200 (33) 577 (109) <0.0001
 Range 175 to 256 488 to 758
Scleral-iris angle (degree) 8.3 (10.89) 30.43 (4.49) 0.0002
 Range 0.82 to 23.8 23.5 to 35.82
Scleral-ciliary process angle (degree) 4.05 (9.40) 40.30 (12.02) <0.0001
 Range −8.19 to 13.71 27.18 to 55.04

This Article

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
View free sample issue >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.