rss
Br J Ophthalmol 84:1177-1184 doi:10.1136/bjo.84.10.1177
  • Original Article
    • Clinical science

Ocular features in Rubinstein-Taybi syndrome: investigation of 24 patients and review of the literature

Table 6

ERG values of 24 patients with Rubinstein-Taybi syndrome

Patient Age ERG
Photopic Scotopic Mixed
Normal values (SD) 137 (64) (n=18) 66 (27) (n=18) 347 (94) (n=18)
a 4 nm nm nm
b 6 7 0 nm
c 6 nm nm nm
d 7 69 53 nm
e 7 20 33 nm
f 8 45 77 218
g 9 nm nm nm
h 10 80 58 305
i 12 82 110 266
j 14 55 94 132
k 15 35 56 nm
l 15 86 82 222
m 15 nm nm nm
n 19 39 0 nm
o 21 nm nm nm
p 24 45 34 112
q 24 53 0 95
r 29 53 99 137
s 30 75 51 280
t 34 27 138 222
u 36 30 nm nm
v 37 36 0 nm
w 43 39 52 nm
x 44 nm nm nm