rss
Br J Ophthalmol 2001;85:1167-1170 doi:10.1136/bjo.85.10.1167
  • Scientific correspondence

Study of retinal nerve fibre layer thickness in eyes with high tension glaucoma and hemifield defect

  1. Michael S Kooka,
  2. Kyung-rim Sunga,
  3. Soontae Kima,
  4. Ryuhwa Parka,
  5. Weechang Kangb
  1. aDepartment of Ophthalmology, University of Ulsan, College of Medicine, Songpa-gu, Seoul, 138–736, Korea, bUnit for Consulting Biostatistics, Asan Medical Center, 388–1 Pungnap-dong, Korea
  1. Michael S Kook, MD Department of Ophthalmology, University of Ulsan, College of Medicine, Asan Medical Center, 388-1 Pungnap-dong, Songpa-gu, Seoul, 138–736, Koreamskook{at}www.amc.seoul.kr
  • Accepted 17 April 2001

Abstract

AIM To quantitatively evaluate retinal nerve fibre layer (RNFL) difference in areas of apparently normal appearing visual field in eyes with high tension glaucoma (HTG) and hemifield defects using scanning laser polarimetry.

METHODS 40 eyes from 40 patients with HTG with superior or inferior hemifield defects based on the Humphrey field analyser (HFA) underwent RNFL thickness measurements. 20 normal eyes from 20 subjects matched in age and refractive error were selected as a control group. The RNFL thickness was measured with a scanning laser polarimeter. Mean RNFL thickness was evaluated in four quadrants (superior, inferior, nasal, and temporal). A superior or inferior quadrant in the defined ring of scanning laser polarimetry corresponds to inferior or superior hemifield in HFA.

RESULTS The mean RNFL thickness in the unaffected quadrant (the quadrant corresponding to the hemifield with apparently normal visual field based on HFA) of the HTG group was significantly thinner than the average RNFL thickness of the corresponding quadrant of the control eyes. The RNFL thickness of the unaffected quadrant in the eyes with HTG was reduced and statistically similar to that of the affected quadrant. Symmetry, calculated as the ratio of superior to inferior RNFL thickness, showed no statistical difference between the study and control group.

CONCLUSION Changes in RNFL are present in the apparently normal hemifield in the eyes with HTG. The thickness of the RNFL is reduced symmetrically in both superior and inferior quadrants based on the GDx parameters.

Footnotes

    Register for free content

    The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.