rss
Br J Ophthalmol 2003;87:413-419 doi:10.1136/bjo.87.4.413
  • Scientific correspondence

Comparison of algorithms for detection of localised nerve fibre layer defects using scanning laser polarimetry

  1. F A Medeiros,
  2. R Susanna, Jr
  1. Department of Ophthalmology, University of São Paulo, São Paulo, Brazil
  1. Correspondence to: Felipe A Medeiros, MD, 5350 Toscana Way No E-111, San Diego, CA 92122, USA; fmedeiros{at}uol.com.br
  • Accepted 14 September 2002

Abstract

Aims: To evaluate different algorithms used to analyse retinal nerve fibre layer thickness (RNFL) data obtained by scanning laser polarimetry, in order to compare their relative abilities to discriminate between patients with glaucomatous localised nerve fibre layer defects and normal subjects.

Methods: 48 eyes of 48 glaucomatous patients with localised RNFL defects and 53 eyes of 53 healthy subjects were included in this study. The localised RNFL defects were identified by RNFL photography and/or slit lamp biomicroscopic examination. All patients were submitted to RNFL examination using scanning laser polarimetry (GDx nerve fibre analyser, Laser Diagnostic Technologies, Inc, San Diego, CA, USA). Three methods of analysis of polarimetry data were used: GDx software provided parameters; RNFL thickness measurements in 16 equal sectors around the optic disc (sectoral analysis); and Fourier analysis of the curve of distribution of RNFL thickness measurements. Linear discriminant functions were developed to assess sensitivity and specificity of the sectoral based analysis and Fourier analysis and were compared to the GDx parameters. In addition, areas under the receiver operating characteristic (ROC) curves were compared.

Results: At a fixed specificity of 91%, the sensitivity of the linear discriminant function from sectoral data (LDF sectoral) was 81%, with an area under the ROC curve of 0.93. The linear discriminant function from Fourier measures had a comparable performance, with an area under the ROC curve of 0.93, and sensitivity of 71% for specificity at 91%. At the same specificity, the sensitivities of the GDx software provided parameters ranged from 15% to 40%. The areas under the ROC curves for the LDF sectoral and LDF Fourier were significantly greater than the ROC curve area for the single best GDx parameter.

Conclusion: The sectoral based analysis and the Fourier analysis of RNFL polarimetry data resulted in an improved detection of eyes with glaucomatous localised nerve fibre layer defects compared to the GDx software provided parameters.

Footnotes

    Register for free content

    The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.