rss
Br J Ophthalmol 88:942-946 doi:10.1136/bjo.2003.026823
  • Clinical science
    • Extended reports

Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure

Table 1

 Case review of Medpor sphere exposure: summary of results

Case (age; sex) Original aetiology and procedure Porous polyethylene orbital sphere implant Anterior cover (in addition to conjunctiva & Tenon’s) Time to 2° motility peg (months) Time from most recent procedure to implant exposure (weeks) Size of defect (mm) Management for complete healing
1 (59 years; F) Trauma; enucleation and acrylic sphere Replacement, 20 mm Implant pseudo-capsule 6 8×8 Temporalis fascia, then donor sclera then buccal mucosa
2 (52 years; F) Trauma; enucleation and glass sphere Replacement, 20 mm None 3 5×7 Temporalis fascia
3 (30 years; M) Tumour retinoblastoma; enucleation Secondary, 16 mm Prolene mesh 32 1 5×10 Topical antibiotic/steroid
4 (41 years; M) Retinal detachment and PVR; evisceration Primary, 20 mm Cap and patch autogenous salvaged sclera 26 51 6×6 Temporalis fascia
5 (40 years; M) Trauma; evisceration Secondary, 20 mm Cap and patch autogenous salvaged sclera 42 3 4×3.5 Temporalis fascia
Mean = 33 Mean = 13