rss
Br J Ophthalmol 2005;89:1289-1292 doi:10.1136/bjo.2005.068056
  • Clinical science
    • Extended reports

Potential of the 1 CU accommodative intraocular lens

  1. G Sauder,
  2. R F Degenring,
  3. B Kamppeter,
  4. P Hugger
  1. Department of Ophthalmology and Eye Hospital, Faculty of Clinical Medicine Mannheim, University of Heidelberg, 68167 Mannheim, Germany
  1. Correspondence to: Dr G Sauder Universitäts-Augenklinik, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany; gangolf.sauderaugen.ma.uni-heidelberg.de
  • Accepted 1 June 2005

Abstract

Aim: To assess the accommodative power of a new foldable monofocal intraocular lens.

Method: A prospective randomised non-masked clinical interventional study. The study included 40 patients attending the hospital for cataract surgery and who were randomly distributed into a study group receiving a new foldable monofocal intraocular lens with flexible haptics, and a control group receiving a standard foldable intraocular lens. Mean follow up period was 8.51 (SD 1.34) months (range 4–11 months) Standard cataract surgery consisted of clear cornea incision, capsulorrhexis, phacoemulsification, and intraocular lens implantation, with topical anaesthesia. The main outcome measures were preoperative and postoperative visual acuity for near and distance; range of accommodation; change in anterior chamber depth.

Results: In the study group compared with the control group, range of accommodation was significantly (p = 0.01) higher (1.01 (SD 0.4) dioptres versus 0.50 (0.11) dioptres) and change in anterior chamber depth was significantly more pronounced (0.82 (0.30) versus 0.40 (0.32), p = 0.01). Both groups did not vary significantly in best corrected vision (0.94 (0.12) versus 0.93 (0.18); p = 0.74).

Conclusion: During a mean follow up period of 8 months after implantation, the new foldable monofocal intraocular lens with flexible haptics showed an accommodative power of about 1 dioptre, which was significantly higher than the accommodative power of a conventional monofocal flexible intraocular lens. The difference in the accommodative power between the two intraocular lenses was paralleled by a difference in the change of the anterior chamber depth.

Footnotes

  • Competing interests: none declared

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.