rss
Br J Ophthalmol 2005;89:1356-1362 doi:10.1136/bjo.2004.064147
  • Laboratory science - Extended reports

Hydroxyapatite promotes superior keratocyte adhesion and proliferation in comparison with current keratoprosthesis skirt materials

  1. J S Mehta1,2,
  2. C E Futter2,
  3. S R Sandeman3,
  4. R G A F Faragher3,
  5. K A Hing4,
  6. K E Tanner4,
  7. B D S Allan1,2
  1. 1Cornea & External Disease Service, Moorfields Eye Hospital, London, UK
  2. 2Division of Cell Biology, Institute of Ophthalmology, London, UK
  3. 3University of Brighton, School of Pharmacy and Biomolecular Science, University of Brighton, Brighton, UK
  4. 4IRC in Biomedical Materials, Queen Mary University of London, London, UK
  1. Correspondence to: MrJ S Mehta Moorfields Eye Hospital, City Road, London EC1V 2PD, UK; jodmehtagmail.com
  • Accepted 18 April 2005

Abstract

Aim: Published clinical series suggest the osteoodontokeratoprosthesis (OOKP) may have a lower extrusion rate than current synthetic keratoprostheses. The OOKP is anchored in the eye wall by autologous tooth. The authors’ aim was to compare adhesion, proliferation, and morphology for telomerase transformed keratocytes seeded on calcium hydroxyapatite (the principal mineral constituent of tooth) and materials used in the anchoring elements of commercially available synthetic keratoprostheses.

Methods: Test materials were hydroxyapatite, polytetrafluoroethylene (PTFE), polyhydroxyethyl methacrylate (HEMA), and glass (control). Cell adhesion and viability were quantified at 4 hours, 24 hours, and 1 week using a calcein-AM/EthD-1 viability/cytotoxicity assay. Focal contact expression and cytoskeletal organisation were studied at 24 hours by confocal microscopy with immunoflourescent labelling. Further studies of cell morphology were performed using light and scanning electron microscopy.

Results: Live cell counts were significantly greater on hydroxyapatite surfaces at each time point (p<0.04). Dead cell counts were significantly higher for PTFE at 7 days (p<0.002). ß1 integrin expression was highest on hydroxyapatite. Adhesion structures were well expressed in flat, spread out keratocytes on both HA and glass. Keratocytes tended to be thinner and spindle shaped on PTFE. The relatively few keratocytes visible on HEMA test surfaces were rounded and poorly adherent.

Conclusions: Keratocyte adhesion, spreading, and viability on hydroxyapatite test surfaces is superior to that seen on PTFE and HEMA. Improving the initial cell adhesion environment in the skirt element of keratoprostheses may enhance tissue integration and reduce device failure rates.

Footnotes

  • Competing interests: none declared

  • This paper was a presentation at the Association for Research in Vision and Ophthalmology, April 2004, Fort Lauderdale, FL, USA.

Responses to this article

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
View free sample issue >>

Free archive
The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.