Article Text

Download PDFPDF
Interpreting the multifocal visual evoked potential: the effects of refractive errors, cataracts, and fixation errors
  1. B J Winn1,
  2. E Shin1,
  3. J G Odel2,
  4. V C Greenstein2,
  5. D C Hood1
  1. 1Department of Psychology, Columbia University, New York, USA
  2. 2Department of Ophthalmology, Columbia University, New York, USA
  1. Correspondence to: D C Hood Department of Psychology, 405 Schermerhorn, Columbia University, New York, NY 10027, USA; dch3columbia.edu

Abstract

Aim: To understand how refractive errors, cataracts, and fixation errors affect multifocal visual evoked potential (mfVEP) responses.

Methods: Monocular mfVEP responses were obtained using a pattern reversal dartboard display. For the control condition, visual acuity was corrected to ⩾20/20 and foveal fixation was maintained. The right eye was tested under the following conditions: simulated refractive error, simulated cataract, steady eccentric fixation, and unsteady fixation.

Results: No subject demonstrated significant abnormalities under control conditions. For the simulated refractive error condition, significant centrally located abnormalities were seen for all subjects. For the simulated cataract condition, significant abnormalities were found for three subjects. The steady eccentric fixation condition yielded abnormalities in both eyes for all subjects while the unsteady fixation condition yielded significant central abnormalities in the tested eye. With eccentric and unsteady fixation conditions, all subjects had at least one sector with a waveform polarity reversal.

Conclusions: While the mfVEP is a useful tool for identifying local optic nerve damage or ruling out non-organic aetiology of visual field defects, factors such as uncorrected refractive errors, cataract, eccentric fixation, and unsteady fixation can produce apparent field defects on the mfVEP. With care, these problems can be correctly identified.

  • mfVEP, multifocal visual evoked potential
  • RMS, root mean square
  • SNR, signal to noise ratio
  • VEP, visual evoked potential
  • visual evoked potential
  • refraction
  • fixation
  • mfVEP, multifocal visual evoked potential
  • RMS, root mean square
  • SNR, signal to noise ratio
  • VEP, visual evoked potential
  • visual evoked potential
  • refraction
  • fixation

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Supported by grant EY02115 from the National Institutes of Health, Bethesda, MD, USA.