rss
Br J Ophthalmol 2005;89:345-351 doi:10.1136/bjo.2004.044990
  • Clinical science
    • Extended reports

Measurement of stray light and glare: comparison of Nyktotest, Mesotest, stray light meter, and computer implemented stray light meter

  1. L J van Rijn1,
  2. C Nischler2,
  3. D Gamer3,
  4. L Franssen4,
  5. G de Wit4,
  6. R Kaper1,
  7. D Vonhoff1,
  8. G Grabner2,
  9. H Wilhelm3,
  10. H J Völker-Dieben1,
  11. T J T P van den Berg4
  1. 1Departement of Ophthalmology, Vrije Universiteit Medical Centre, Amsterdam, Netherlands
  2. 2Landesklinik für Augenheilkunde und Optometrie, Salzburg, Austria
  3. 3Universitäts-Augenklinik, Tübingen, Germany
  4. 4The Netherlands Ophthalmic Research Institute, Amsterdam, Netherlands
  1. Correspondence to: Dr L J van Rijn Vrije Universiteit Medical Centre, PO Box 7057, NL-1007 MB Amsterdam, Netherlands; vanrijnvumc.nl
  • Accepted 2 June 2004

Abstract

Aim: To evaluate the properties of devices for measuring stray light and glare: the Nyktotest, Mesotest, “conventional” stray light meter and a new, computer implemented version of the stray light meter.

Methods: 112 subjects, divided in three groups: (1) young subjects without any eye disease; (2) elderly subjects without any eye disease, and (3) subjects with (early) cataract in at least one eye. All subjects underwent a battery of glare and stray light tests, measurement of visual acuity, contrast sensitivity, refraction, and LOCS III cataract classification. Subjects answered a questionnaire on perceived disability during driving.

Results: Repeatability values were similar for all glare/stray light tests. Validity (correlation with LOCS III and questionnaire scores), discriminative ability (ability to discriminate between the three groups), and added value (to measurement of visual acuity and contrast sensitivity) were all superior for both stray light meters. Results of successive measurements are interrelated for the conventional but not the new stray light meter. This indicates a better resistance to fraud for the latter device.

Conclusions: The new computer implemented stray light meter is the most promising device for future stray light measurements.

Footnotes

    This Article

    Services

    1. Request permissions

    Responses

    1. Submit a response
    2. No responses published

    Social bookmarking

    Register for free content


    Free sample
    This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
    View free sample issue >>

    Free archive
    The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
    Register to access the free archive >>

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.