rss
Br J Ophthalmol 89:489-492 doi:10.1136/bjo.2004.052498
  • Clinical science
    • Extended reports

Correlation between retinal nerve fibre layer thickness and optic nerve head size: an optical coherence tomography study

Table 2

 Correlation between RNFL thickness and ONH parameters

RNFL thickness Optic disc area Cup area Rim area Vertical C:D ratio Horizontal C:D ratio Vertical diameter Horizontal diameter
RNFL, retinal nerve fibre layer; ONH, optic nerve head.
C:D ratio, cup:disc ratio.
360° average R = 0.4985 R = 0.0951 R = 0.4024 R = 0.0879 R = 0.0610 R = 0.4454 R = 0.4301
p = 0.0001 p = NS p = 0.0026 p = NS p = NS p = 0.0007 p = 0.0012
Temporal quadrant R = 0.2026 R = −0.1263 R = 0.2952 R = −0.1537 R = −0.2067 R = 0.1838 R = 0.1599
p = NS p = NS p = 0.0302 p = NS p = NS p = NS p = NS
Superior quadrant R = 0.3822 R = −0.003 R = 0.3474 R = 0.0677 R = 0.0395 R = 0.3774 R = 0.2971
p = 0.0043 p = NS p = 0.0101 p = NS p = NS p = 0.0049 p = 0.0291
Nasal quadrant R = 0.3024 R = 0.1552 R = 0.1274 R = 0.1485 R = 0.1505 R = 0.1490 R = 0.2752
p = 0.026 p = NS p = NS p = NS p = NS p = NS p = 0.044
Inferior quadrant R = 0.4048 R = 0.1160 R = 0.3199 R = 0.0424 R = 0.0301 R = 0.2793 R = 0.3970
p = 0.0024 p = NS p = 0.0184 p = NS p = NS p = 0.0408 p = 0.0030

This Article

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
View free sample issue >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.