rss
Br J Ophthalmol 2006;90:1259-1262 doi:10.1136/bjo.2004.097022
  • Clinical science
    • Scientific reports

Influence of cataract on optical coherence tomography image quality and retinal thickness

  1. M E J van Velthoven1,
  2. M H van der Linden2,
  3. M D de Smet1,
  4. D J Faber3,
  5. F D Verbraak1
  1. 1Department of Ophthalmology, Academic Medical Centre, Amsterdam, The Netherlands
  2. 2OMC Haarlem, Haarlem, The Netherlands
  3. 3Laser Centre, Academic Medical Centre
  1. Correspondence to: M E J van Velthoven Department of Ophthalmology, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands; m.e.vanvelthoven{at}amc.uva.nl
  • Accepted 3 July 2006

Abstract

Background: As optical coherence tomography (OCT) is widely used for diagnosis and monitoring of ocular pathology, especially in the elderly people, the influence of cataract on image quality and macular retinal thickness was studied.

Methods: In 29 patients scheduled for cataract surgery, preoperative and postoperative OCT scans were obtained. Cataracts were categorised as nuclear, posterior or cortical. Parameters for image quality (signal-to-noise ratio (SNR)) and signal strength and macular thickness were compared. A three-level expert grading scale was used to evaluate the discriminative abilities of SNR and signal strength.

Results: Nuclear cataracts (n = 12) provided better preoperative scans (higher SNR/signal strength) than posterior (n = 7) and cortical (n = 10) cataracts (p<0.004). Postoperatively SNR and signal strength increased significantly in all patients (p<0.001). The SNR was better at discriminating poor from acceptable and good scans than signal strength (area under the receiver operating curve: 0.879 and 0.810, respectively). Postoperative macular thickness overall showed a significant increase (p = 0.005), most evident in patients with posterior cataracts (p = 0.028).

Conclusions: OCT imaging is influenced by cataract; image quality is reduced preoperatively and macular thickness measurements are slightly increased postoperatively. In individual patients, OCT scans remain reliable for gross clinical interpretation, even in the presence of cataract.

Footnotes

  • Competing interests: None.

  • Published Online First 19 July 2006

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
View free sample issue >>

Free archive
The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.