rss
Br J Ophthalmol 2006;90:693-696 doi:10.1136/bjo.2006.090951
  • Clinical science
    • Scientific reports

Subjective and objective performance of the Lenstec KH-3500 “accommodative” intraocular lens

  1. J S Wolffsohn1,
  2. S A Naroo1,
  3. N K Motwani3,
  4. S Shah3,
  5. O A Hunt1,
  6. S Mantry3,
  7. M Sira3,
  8. I A Cunliffe3,
  9. M T Benson3
  1. 1School of Life and Health Sciences, Aston University, Birmingham B4 7ET, UK
  2. 2Midland Eye Institute, 50 Lode Lane, Birmingham B91 2AW, UK
  3. 3Birmingham and Midland Eye Centre, Dudley Road, Birmingham B18 7QU, UK
  1. Correspondence to: J S Wolffsohn School of Life and Health Sciences, Aston University, Aston Triangle, Birmingham, UK; j.s.w.wolffsohn{at}aston.ac.uk
  • Accepted 23 February 2006
  • Published Online First 10 March 2006

Abstract

Aim: To determine whether eyes implanted with the Lenstec KH-3500 “accommodative” intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs.

Methods: 28 participants were implanted monocularly with a KH-3500 “accommodative” IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at ~3 weeks and repeated after 6 months.

Results: Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) μm and lower order were 0.24 (0.39) μm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05).

Conclusions: The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this “accommodative” ability of the lens appears to have decreased by 6 months post-surgery.

Footnotes

  • No financial support was received for this study and none of the authors have any commercial connection with any of the products or companies mentioned in this paper.

This Article

  1. All Versions of this Article:
    1. bjo.2006.090951v1
    2. 90/6/693 most recent

Services

  1. Request permissions

Responses

  1. Submit a response
  2. No responses published

Social bookmarking

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
View free sample issue >>

Free archive
The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.