rss
Br J Ophthalmol 2007;91:1364-1368 doi:10.1136/bjo.2007.120980
  • Extended report
    • Clinical science - Extended reports

Novel pressure-to-cornea index in glaucoma

  1. Milko E Iliev1,
  2. Alexander Meyenberg1,
  3. Ernst Buerki2,
  4. George Shafranov3,
  5. M Bruce Shields3
  1. 1
    Department of Ophthalmology, University of Bern, Inselspital, Bern, Switzerland
  2. 2
    Private practice, Ophthalmologists Association Thun, Thun, Switzerland
  3. 3
    Department of Ophthalmology & Visual Science, Yale University School of Medicine, New Haven, CT, USA
  1. Milko E Iliev, MD, Department of Ophthalmology, University of Bern, Inselspital, 3010 Bern, Switzerland; milko.iliev{at}insel.ch
  • Accepted 25 April 2007
  • Published Online First 10 May 2007

Abstract

Background: Several conversion tables and formulas have been suggested to correct applanation intraocular pressure (IOP) for central corneal thickness (CCT). CCT is also thought to represent an independent glaucoma risk factor. In an attempt to integrate IOP and CCT into a unified risk factor and avoid uncertain correction for tonometric inaccuracy, a new pressure-to-cornea index (PCI) is proposed.

Methods: PCI (IOP/CCT3) was defined as the ratio between untreated IOP and CCT3 in mm (ultrasound pachymetry). PCI distribution in 220 normal controls, 53 patients with normal-tension glaucoma (NTG), 76 with ocular hypertension (OHT), and 89 with primary open-angle glaucoma (POAG) was investigated. PCI’s ability to discriminate between glaucoma (NTG+POAG) and non-glaucoma (controls+OHT) was compared with that of three published formulae for correcting IOP for CCT. Receiver operating characteristic (ROC) curves were built.

Results: Mean PCI values were: Controls 92.0 (SD 24.8), NTG 129.1 (SD 25.8), OHT 134.0 (SD 26.5), POAG 173.6 (SD 40.9). To minimise IOP bias, eyes within the same 2 mm Hg range between 16 and 29 mm Hg (16–17, 18–19, etc) were separately compared: control and NTG eyes as well as OHT and POAG eyes differed significantly. PCI demonstrated a larger area under the ROC curve (AUC) and significantly higher sensitivity at fixed 80% and 90% specificities compared with each of the correction formulas; optimum PCI cut-off value 133.8.

Conclusions: A PCI range of 120–140 is proposed as the upper limit of “normality”, 120 being the cut-off value for eyes with untreated pressures ≤21 mm Hg, 140 when untreated pressure ≥22 mm Hg. PCI may reflect individual susceptibility to a given IOP level, and thus represent a glaucoma risk factor. Longitudinal studies are needed to prove its prognostic value.

Footnotes

  • Competing interests: None.

  • Abbreviations:
    CCT

    central corneal thickness

    IOP

    intraocular pressure

    NTG

    normal-tension glaucoma

    OHT

    ocular hypertension

    PCI

    pressure-to-cornea index

    POAG

    primary open-angle glaucoma

    ROC

    receiver operating characteristic

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.