rss
Br J Ophthalmol 2007;91:1373 doi:10.1136/bjo.2007.129213
  • Video Report

Sub-epithelial gas breakthrough during femtosecond laser flap creation for LASIK

  1. Sathish Srinivasan,
  2. Sheldon Herzig
  1. Herzig Eye Institute, Toronto and Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada
  1. Sathish Srinivasan, Herzig Eye Institute, Toronto and Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada; sathish{at}tiscali.co.uk

    Abstract

    Introduction: The femtosecond laser produces photodisruption at the molecular level to generate plasma, displacing the surrounding tissue resulting in the formation of cavitation bubbles. We report a case of myopic LASIK in which a vertical gas break through the surface occurred during IntraLase femtosecond flap creation.

    Case report: A 30 year-old patient underwent bilateral Wavefront guided (WaveScan, Visx, USA) LASIK. The IntraLase (FS 60) was used to create a 100 μm flap. In the right eye, during flap creation in a raster mode, subepithelial gas breakthrough was noted in two focal areas. The surgeon was able to lift the flap without creating a buttonhole. The excimer ablation procedure was performed and the flap was repositioned. On the first postoperative day uncorrected visual acuity was 20/20 in both eyes.

    Discussion: The incidence of flap-related complications associated with the use of motorized microkeratomes for creating corneal flap during LASIK is around 5%.1 2 For the femtosecond laser there have been previous reports of cavitation bubbles migrating to the anterior chamber resulting in poor tracking during subsequent excimer laser ablation.3 4 Vertical subepithelial gas breakthrough during femtosecond laser flap creation is rare and a PubMed search revealed no previous report of this complication. Vertical gas breakthrough occurs between the dissection plane and the subepithelial space resulting in escape of gas bubbles in to the subepithelial space. The cause is unknown but a thin flap or a focal break in the Bowman’s membrane may contribute to this complication.

    Footnotes

    Register for free content

    The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.