rss
Br J Ophthalmol 91:891-894 doi:10.1136/bjo.2007.114082
  • Clinical science
    • Scientific reports

Finger’s “slotted” eye plaque for radiation therapy: treatment of juxtapapillary and circumpapillary intraocular tumours

Table 1

 Finger’s slotted plaque radiation therapy

Example of tumours Plaque size Slot width Slot length Source Dose (tumour) Prescription (point–axial) Dose (optic disc) Dose (fovea)
I, iodine; Pd, palladium; Ru, ruthenium.
*See fig 2c.
Juxtapapillary
10×10×5 16 8 6 Pd-103 85 5 167.9 80.19
10×10×5 16 8 6 I-125 85 5 135.9 64.9
10×10×5 16 8 6 Ru-106 85 5 64.4 8.5
Barely circumpapillary*
12×12×5 18 8 8 Pd-103 85 5 144.9 67.54
12×12×5 18 8 8 I-125 85 5 135.3 68.7
12×12×5 18 8 8 Ru-106 85 5 229.3 59.19
Moderately circumpapillary
14×14×5 20 8 10 Pd-103 85 5 152.2 94.6
14×14×5 20 8 10 I-125 85 5 136.7 85
14×14×5 20 8 10 Ru-106 85 5 276.7 123.5
Largely circumpapillary
16×16×5 22 8 12 Pd-103 85 5 149.7 97.35
16×16×5 22 8 12 I-125 85 5 171 110.3
16×16×5 22 8 12 Ru-106 85 5 423.5 220.4