rss
Br J Ophthalmol 2007;91:933-938 doi:10.1136/bjo.2006.110437
  • Clinical science
    • Extended reports

Glaucoma detection with matrix and standard achromatic perimetry

  1. Zvia Burgansky-Eliash*,
  2. Gadi Wollstein*,
  3. Avni Patel,
  4. Richard A Bilonick,
  5. Hiroshi Ishikawa,
  6. Larry Kagemann,
  7. William D Dilworth,
  8. Joel S Schuman
  1. Department of Ophthalmology, UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, University of Pittsburgh School of Medicine,Pittsburgh, Pennsylvania, USA
  1. Correspondence to: Dr J S Schuman Department of Ophthalmology, UPMC Eye Center, Eye and Ear Institute, Suite 816, University of Pittsburgh School of Medicine, 203 Lothrop Street, Pittsburgh, PA 15213, USA; schumanjs{at}upmc.edu
  • Accepted 3 January 2006
  • Published Online First 10 January 2007

Abstract

Background: Matrix perimetry is a new iteration of frequency-doubling technology (FDT) which uses a smaller target size in the standard achromatic perimetry presentation pattern.

Aim: To compare the performance of matrix and Swedish interactive thresholding algorithm (SITA) perimetry in detecting glaucoma diagnosed by structural assessment.

Design: Prospective cross-sectional study.

Methods: 76 eyes from 15 healthy subjects and 61 consecutive glaucoma suspects and patients with glaucoma were included. All patients underwent optic nerve head (ONH) photography, SITA and matrix perimetries, and optical coherence tomography (OCT) within a 6-month period. Glaucoma diagnosis was established by either glaucomatous optic neuropathy or OCT by assessing retinal nerve fibre layer (RNFL) thickness. Mean deviation (MD), pattern standard deviation (PSD), glaucoma hemifield test and cluster of abnormal testing locations were recorded from matrix and SITA perimetries.

Results: Similar correlations were observed with matrix and SITA perimetry MD and PSD with either cup-to-disc ratio or OCT mean RNFL. The area under the receiver operating characteristic (AROC) curves of MD and PSD for discriminating between healthy and glaucomatous eyes ranged from 0.69 to 0.81 for matrix perimetry and from 0.75 to 0.77 for SITA perimetry. There were no significant differences among any corresponding matrix and SITA perimetry AROCs.

Conclusions: Matrix and SITA perimetries had similar capabilities for distinguishing between healthy and glaucomatous eyes regardless of whether the diagnosis was established by ONH or OCT–RNFL assessment.

Footnotes

  • * ZB-E and GW had equal roles in preparation of the manuscript.

  • Published Online First 10 January 2007

  • Funding: This study is supported in part by National Institute of Health grants RO1-EY013178-6, P30-EY008098 (Bethesda, Maryland, USA), The Eye and Ear Foundation (Pittsburgh, Pennsylvania, USA) and an unrestricted grant from Research to Prevent Blindness, (New York, New York, USA).

  • Competing interests: JSS receives royalties for intellectual property licensed to Carl Zeiss Meditec, Dublin, California, USA.

This Article

  1. All Versions of this Article:
    1. bjo.2006.110437v1
    2. 91/7/933 most recent

Services

  1. Request permissions

Responses

  1. Submit a response
  2. No responses published

Social bookmarking

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
View free sample issue >>

Free archive
The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.