rss
Br J Ophthalmol 2008;92:108-111 doi:10.1136/bjo.2007.121533
  • Original Article
    • Laboratory science

Fluorophotometric measurement of the precorneal residence time of topically applied hyaluronic acid

This article has been Unlocked
  1. H Mochizuki1,
  2. M Yamada1,
  3. S Hato1,
  4. T Nishida2
  1. 1
    Division for Vision Research, National Institute of Sensory Organs, National Tokyo Medical Center, Tokyo, Japan
  2. 2
    Department of Ophthalmology, Yamaguchi University Graduate School of Medicine, Yamaguchi, Japan
  1. M Yamada, Division for Vision Research, National Institute of Sensory Organs, National Tokyo Medical Center, 2-5-1 Higashigaoka, Meguro, Tokyo 152-8902, Japan; yamadamasakazu{at}kankakuki.go.jp
  • Accepted 6 June 2007

Abstract

Purpose: This study was performed to separately assess the aqueous flow applied with hyaluronic acid, and the behaviour of hyaluronic acid itself on the ocular surface.

Methods: Two different fluorescent dyes, fluorescein sodium dissolved in 0.1% hyaluronic acid (HA) solution and 0.1% fluorescein conjugated with hyaluronic acid (F-HA) dissolved in saline, were used. A volume of 20 μl of tested solution was applied to the eye of 10 healthy volunteers. Fluorescein sodium dissolved in saline served as a control. The fluorescent intensity of the precorneal tear film was measured at the central cornea every minute for 10 min. The turnover rate was calculated using the equation that plots fluorescent intensity against time in a semilog plot and expressed as %/min.

Results: Turnover rates of topically applied 0.1% F-HA, 0.1% HA and saline were 8.1 (SD 3.6)%/min, 21.6 (2.8)%/min, and 31.0 (3.7)%/min, respectively. The turnover rate of F-HA was significantly lower than those of HA and saline (p = 0.00012 and p = 0.00000022, respectively; Mann–Whitney test). The turnover rate of HA was significantly lower than that of saline (p = 0.00001; Mann–Whitney test).

Conclusion: Our results indicate that the bulk aqueous flow applied with HA and the turnover of HA itself are different. HA molecules may adhere to the ocular surface by surface-chemical and/or biochemical properties. The long retention time of HA on the ocular surface may explain the mechanism in which hyaluronic acid has been shown to enhance tear film stability for a few hours.

Footnotes

  • Competing interests: The authors have no proprietary interest in any materials in this manuscript.

This article has been Unlocked

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
View free sample issue >>

Free archive
The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.