rss
Br J Ophthalmol 2008;92:1693-1694 doi:10.1136/bjo.2007.129585
  • Innovations

Removal of retained subretinal perfluorocarbon liquid

  1. J García-Arumí,
  2. P Castillo,
  3. M López,
  4. A Boixadera,
  5. V Martínez-Castillo,
  6. L Pimentel
  1. Instituto de Microcirugía Ocular, Barcelona, Spain
  1. Dr J García Arumí, Instituto de Microcirugía Ocular, C/Munner n° 10, 08022, Barcelona, Spain; 17215jga{at}comb.es
  • Accepted 20 January 2008

Abstract

Aim: To report a case series in which a modified technique was used to remove retained subretinal perfluorocarbon liquid.

Method: In three patients with retained subretinal perfluorocarbon liquid, a three-port pars plana vitrectomy approach was used to perform a small self-sealing retinotomy adjacent to the perfluorocarbon liquid bubble. The tip of a 50-G glass micropipette connected to an active suction system was inserted in the bubble, and the liquid was aspirated.

Results: Successful removal of subretinal perfluorocarbon liquid was achieved in all cases with no complications. Visual acuity improved in all patients.

Conclusion: With the technique presented, retained subretinal perfluorocarbon liquid can be successfully removed with minimal trauma to adjacent tissues.

Footnotes

  • Competing interests: None.

  • Ethics approval: Ethics approval was provided by Instituto de Microcirugía Ocular, Barcelona, Spain.

  • Patient consent: Obtained.

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.