Opaque intraocular lens for intractable diplopia: experience and patients’ expectations and satisfaction

  1. O H Hadid1,
  2. N K Wride1,
  3. P G Griffiths1,
  4. N P Strong1,
  5. M P Clarke1,2
  1. 1
    Department of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne, UK
  2. 2
    School of Neurobiology, Neurology and Psychiatry, Faculty of Medicine, Newcastle University, Newcastle upon Tyne, UK
  1. Mr O H Hadid, Department of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne NE1 4LP, UK; omar_hadid{at}hotmail.com
  • Accepted 30 March 2008
  • Published Online First 12 June 2008

Abstract

Aim: To report the authors' experience with the use of opaque intraocular lenses (IOL) in diplopia unresponsive to traditional management strategies, and to assess patients’ satisfaction and the visual function of patients following insertion of opaque IOL using the Visual Function Index (VF-14).

Settings: Royal Victoria Infirmary, Newcastle upon Tyne, UK.

Method: Data were obtained on all patients who underwent insertion of an opaque IOL at our institution between 2002 and 2006. Patients were interviewed by telephone. Any visual function impairment was assessed using the VF-14 questionnaire. Patients were also asked to score subjectively their overall satisfaction with the visual outcome after opaque IOL insertion.

Results: The authors studied 12 patients (n = 12) who had insertion of opaque IOL. All patients had constant and persistent diplopia unresponsive to other treatments acceptable to the patient. The median duration of diplopia was 5.5 years (interquartile range was 2.4–17.3 years). The postoperative VF-14 ranged from 75 to 100, and the mean VF-14 was 91 (95% CI 83–99). Three patients reported a maximum score of 100. Patient satisfaction ranged from 2 to 4, and the average was 3.4 out of 4.

Conclusions: Opaque IOL insertion is a valuable option in the management of intractable diplopia. The VF-14 revealed very little or no impairment in visual function following the procedure. All patients reported improvement in their visual function and were pleased with the final outcome.

Footnotes

  • Competing interests: None.

  • Ethics approval: As this study was a service evaluation, formal ethics committee approval was not required.

  • Patient consent: Informed consent was obtained from all patients prior to surgery emphasising the risk of delaying or missing a diagnosis of primary posterior pole pathology.

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
View free sample issue >>

Free archive
The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.