rss
Br J Ophthalmol 2009;93:1096-1100 doi:10.1136/bjo.2008.144873
  • Original Article
  • Laboratory science

New tool for the simultaneous detection of 10 different genotypes of Acanthamoeba available from the American Type Culture Collection

  1. P Goldschmidt1,
  2. S Degorge1,
  3. D Benallaoua1,
  4. C Saint-Jean1,
  5. L Batellier1,
  6. C Alouch2,
  7. L Laroche2,
  8. C Chaumeil1
  1. 1
    Laboratoire du Centre National d’Ophtalmologie des Quinze-Vingts, Paris, France
  2. 2
    Service 5, Centre National d’Ophtalmologie des Quinze-Vingts, Paris, France
  1. Correspondence to Dr P Goldschmidt, Laboratoire du Centre National d’Ophtalmologie des Quinze-Vingts, 28 rue de Charenton, 75012 Paris, France; pablogol{at}aol.com
  • Accepted 17 March 2009
  • Published Online First 28 April 2009

Abstract

Background: Acanthamoeba keratitis (AK) is a sight-threatening infection, and none of the current diagnosis tests are able to detect in one reaction low levels of the vast majority of strains associated with pathology. The goal of this work was to validate a new tool for the detection of the American Type Cell Collection (ATCC) referenced Acanthamoeba monitoring simultaneously DNA extraction yields and PCR inhibitors. Performances were assessed on corneal scrapings.

Methods: Primers were selected in a region bracketing a 41 591 bp of the A castellanii mitochondrion gene. DNA extraction and PCR inhibitors were monitored by adding an internal control (virus). Acanthamoeba were detected and quantified by the real-time fast-duplex TaqMan PCR (f-d-real-t PCR) and negativity confirmed by SYBR Green real-time PCR.

Results: The f-d-real-t PCR detects 0.1 cyst/μl or less of the 10 referenced strains (sensitivity slightly lower for Aastronyxis). Bacteria, fungi and herpesviruses do not cross-react. The specificity and sensitivity of the f-d-real-t PCR were higher than culture and other real-time PCR on 20 keratitis samples.

Conclusion: The f-d-real t PCR detects in less than 2 h the Acanthamoeba strains available from the ATCC with a higher sensitivity and specificity than techniques previously reported. Larger trials are necessary to validate its usefulness for disease management and environmental studies.

Footnotes

  • Competing interests None.

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.