Article Text

Download PDFPDF
Repeatability of measurements of effectiveness of glaucoma medication
  1. Alan P Rotchford1,
  2. Anthony J King2
  1. 1Department of Ophthalmology, Tennent Institute of Ophthalmology, Gartnavel Hospital, Glasgow, UK
  2. 2Department of Ophthalmology, Nottingham University Hospital, Queen's Medical Centre, Nottingham, UK
  1. Correspondence to Alan P Rotchford, Department of Ophthalmology, Tennent Institute of Ophthalmology, Gartnavel Hospital, Great Western Road, Glasgow G12 0YN, UK; rotchford{at}doctors.org.uk

Abstract

Aims To determine short-term repeatability of the effect of intraocular pressure (IOP) reducing medication and the number of repeated measurements necessary to estimate therapeutic effect with a given degree of precision.

Methods IOP was measured at 8:00, 11:00 and 16:00 h at each of three weekly visits in untreated patients with primary open-angle glaucoma or ocular hypertension. After starting travaprost (0.004%) to both eyes, the measurements were repeated for a further three weekly visits. Repeatability of the change in IOP 1, 2 and 3 weeks after starting treatment was reported as the coefficient of repeatability (CR) and coefficient of variability (CV).

Results Mean reduction in IOP was 7.5 mm Hg (29.9%). CR and CV between visits were 7.8 mm Hg and 37.2%, respectively. Repeated estimates of the effectiveness of treatment in the same subject at the same time of day would, therefore, be expected to lie within a range of 7.8 mm Hg and within ±73.2% of the mean effect with 95% confidence. A reduction in IOP less than 7.8 mm Hg over a single pair of measurements would be indistinguishable from measurement error. Precision improves from ±73.2% for a single pair of readings to ±25.9% for eight pairs.

Conclusions Day-to-day repeatability in the estimation of medication effectiveness is poor even for time-of-day standardised measurements and the number of IOP measurements required to achieve precision adequate for use in clinical practice is large.

  • Glaucoma
  • Intraocular pressure
  • Diagnostic tests/Investigation

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Linked Articles

  • At a glance
    Harminder Singh Dua Arun D Singh