rss
Br J Ophthalmol doi:10.1136/bjo.2009.167775
  • Clinical Science

Measurement of corneal aberrations for customization of intraocular lens asphericity: impact on quality of vision after micro-incision cataract surgery.

  1. Yannick Nochez*,
  2. Anne Favard,
  3. Samuel Majzoub,
  4. Pierre-Jean Pisella
  1. CHU Bretonneau, Université Francois Rabelais, France
  1. Correspondence to: Yannick Nochez, CHU Bretonneau, Boulevard Tonnelle, Service d'ophtalmologie du Pr PISELLA, TOURS, 37000, France; yannick.nochez{at}free.fr
  • Received 3 July 2009
  • Accepted 27 August 2009
  • Published Online First 14 October 2009

Abstract

Aims: To compare the quality of vision of patients with customized-aspheric intraocular lenses (IOL) versus patients implanted with zero-aberration IOL after a 1.8 mm micro-incision cataract surgery (MICS).

Methods: 43 eyes were divided into two groups: 17 eyes (reference group) received zero aberration Acri.Smart 46LC® (Carl Zeiss Meditec, Germany) and 26 eyes received a customized-aspheric IOL: either aspherical Acri.Smart 36A® generating a -0.18 µm SA compensation equivalent, or zero-aberration Acri.Smart 46LC®. IOL asphericity was individually selected according to the corneal spherical aberration (SA) in order to produce a residual ocular SA close to +0.10 µm. Refraction, best-corrected visual acuity (BCVA), contrast sensitivities, ocular wavefront aberrations, and objective quality of vision assessment were analyzed 6 months after MICS.

Results: Postoperative BCVA was similar in both groups (p=0.58). Mesopic contrast sensitivities were significantly better in the custom group at intermediate and high spatial frequencies (p<0.001), while photopic contrast sensitivities were similar. Total SA was significantly lower in the custom group (Z40 = 0.085 ± 0.075 µm versus 0.261 ± 0.091 µm, p<0.001) whereas no difference was found in preoperative corneal SA. Modulation Transfer Function (MTF) cutoff frequency was higher in the custom group than in the reference group (34.3 ± 8.1 c/deg versus 23.57 ± 8.6 c/deg respectively, p=0.008).

Conclusion: Individual selection of IOL asphericity with a preoperative corneal SA measurement allowed control of final ocular SA. Such customization improves mesopic contrast sensitivity, and leads to better objective quality of vision.

Footnotes

    Relevant Article

    Register for free content


    Free sample
    This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of BJO.
    View free sample issue >>

    Free archive
    The full back archive is now available for BJO. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
    Register to access the free archive >>

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.