Skip to main content

Advertisement

Log in

Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis

  • Clinical Investigation
  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract 

Background: The precision of intraocular lens (IOL) calculation is essentially determined by the accuracy of the measurement of axial length. In addition to classical ultrasound biometry, partial coherence interferometry serves as a new optical method for axial length determination. A functional prototype from Carl Zeiss Jena implementing this principle was compared with immersion ultrasound biometry in our laboratory. Patients and methods: In 108 patients attending the biometry laboratory for planning of cataract surgery, axial lengths were additionally measured optically. Whereas surgical decisions were based on ultrasound data, we used postoperative refraction measurements to calculate retrospectively what results would have been obtained if optical axial length data had been used for IOL calculation. For the translation of optical to geometrical lengths, five different conversion formulas were used, among them the relation which is built into the Zeiss IOLMaster. IOL calculation was carried out according to Haigis with and without optimization of constants. Results: On the basis of ultrasound immersion data from our Grieshaber Biometric System (GBS), postoperative refraction after implantation of a Rayner IOL type 755U was predicted correctly within ±1 D in 85.7% and within ±2 D in 99% of all cases. An analogous result was achieved with optical axial length data after suitable transformation of optical path lengths into geometrical distances. Conclusions: Partial coherence interferometry is a non- contact, user- and patient-friendly method for axial length determination and IOL planning with an accuracy comparable to that of high-precision immersion ultrasound.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 8 March 2000 Revised: 22 May 2000 Accepted: 8 June 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Haigis, W., Lege, B., Miller, N. et al. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefe's Arch Clin Exp Ophthalmol 238, 765–773 (2000). https://doi.org/10.1007/s004170000188

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004170000188

Keywords

Navigation