Comparison of the fluoroquinolones based on pharmacokinetic and pharmacodynamic parameters

Pharmacotherapy. 2000 Apr;20(4):417-28. doi: 10.1592/phco.20.5.417.35062.

Abstract

Assessment of pharmacodynamic activity from standard in vitro minimum inhibitory concentrations (MICs) alone is insufficient to predict in vivo potency. Achievable serum and tissue concentrations as well as pharmacokinetic characteristics must be considered. When pharmacokinetic and pharmacodynamic values are combined, the area under the inhibitory curve (AUIC) and peak concentration:MIC ratio predict clinical cure for fluoroquinolones. Clinical data and animal models indicate that a peak:MIC of 10:1 and above and an AUIC of 125 and above are predictive of a clinical cure for this class of antimicrobials against gram-negative organisms. The values may be used to compare and contrast fluoroquinolones to determine which would be best for treating a specific microorganism. Pharmacodynamic data also can be used to design regimens that minimize the risk of suboptimal drug levels. Ensuring the optimal fluoroquinolone dosage based on pharmacodynamic principles would diminish the emergence of resistant organisms and prevent treatment failures.

Publication types

  • Comparative Study
  • Review

MeSH terms

  • Anti-Infective Agents / pharmacokinetics*
  • Anti-Infective Agents / pharmacology*
  • Area Under Curve
  • Bacteria / drug effects
  • Fluoroquinolones
  • Half-Life
  • Humans
  • Metabolic Clearance Rate
  • Microbial Sensitivity Tests

Substances

  • Anti-Infective Agents
  • Fluoroquinolones