Table 3

Relation of the capsulorhexis contact to the IOL optic and the presence of LECs at 90 days, for each IOL type

Rhexis completely on (n=20)Rhexis partly off (n=53)Rhexis completely off (n=8)
No LEC LEC No LEC LEC No LEC LEC
PMMA (n=28)1501903
Silicone (n=27)2302002
Polyacrylic (n=26)905903
Total (n=81)12 (60%)8 (40%)5 (9%)48 (91%)0 (0%)8 (100%)