Flash intensity (cd/s/m) | Pearson correlation between interocular differences in mean deviation and interocular differences of: | ||||
---|---|---|---|---|---|
b-Wave amplitude | Implicit time | ||||
Correlation coefficient | p Value | Correlation coefficient | p Value | ||
9.4 | –0.405 | 0.02 | 0.554 | 0.001 | |
5.3 (–0.25 log) | –0.38 | 0.03 | 0.638 | <0.001 | |
3.0 (–0.5 log) | –0.366 | NS | 0.735 | <0.001 | |
1.7 (–0.75 log) | –0.498 | 0.003 | 0.582 | <0.001 | |
0.53 (–1.25 log) | –0.465 | 0.006 | 0.237 | NS | |
0.17 (–1.75 log) | –0.521 | 0.002 | 0.0.383 | 0.03 | |
0.053 (–2.25 log) | –0.443 | 0.01 | 0.106 | NS | |
0.017 (–2.75 log) | –0.386 | 0.03 | 0.288 | NS | |
0.0053 (–3.25 log) | –0.268 | NS | 0.321 | NS | |
0.00053 (–4.25 log) | 0.187 | NS | 0.356 | NS |
The table shows the flash intensities for which interocular differences in the mean deviation between both fellow eyes of the glaucoma patients correlated significantly with the interocular differences of the b-wave amplitudes and implicit times. Correlation was better for implicit times than for b-wave amplitudes.
↵p⩽0.05,
↵p⩽0.005,
↵p⩽0.001.