Table 3

Relationship of iris parameters and risk of angle closure (combined groups)

Iris measuresUnadjusted OR (95% CI)*p ValueMultivariate adjusted OR (95% CI)* p Value
IT 7501.3 (1.1, 1.6)0.0011.7 (1.1, 2.7)0.032
IT 20001.4 (1.2, 1.7)<0.0012.2 (1.3, 3.8)0.006
ITM1.5 (1.2, 1.8)<0.0012.2 (1.3, 3.6)0.003
I-Area1.0 (0.9, 1.1)0.8801.1 (1.0, 1.3)0.083
I-Curv0.5 (0.4, 0.6)<0.0010.4 (0.3, 0.5)<0.001
  • * Per 0.1 unit increase.

  • Multivariate adjusted for age, sex, pupil size and anterior chamber depth.

  • IT750, iris thickness measured at 750 μm from the sclera spur; IT2000, iris thickness measured at 2000 μm from the sclera spur; I-Area, iris area; ITM, maximal iris thickness; I-Curv, iris curvature.