Author | Procedure | Study design | Number of eyes | UCNVA | BDCNVA | Additional tests | Complications |
---|---|---|---|---|---|---|---|
Levinger et al4 | Monovision induced by LASIK | 1 year | 38 | 0.06 logMAR (binocular | Not available | ▸ CS reduced in mesopic condition. ▸ Near stereoacuity 57 s of arc ▸ 85.2% of satisfaction | Not reported |
Greenbaum6 | Monovision pseudophakia | 1 year | 120 cataract/20 CLE | 0.0 logMAR or better (binocular) in 91% cataract and 95% CLE | Not available | ▸ 91% acceptance cataract ▸ 95% acceptance CLE | ▸ 1 dry eye ▸ 1 vitreous loss ▸ 1 iris atrophy ▸ 20% reported haloes and glare in cataract in CLE |
Uthoff et al17 | Multifocal corneal ablation | 6 months | 20 (emmetropic), 20 (hyperopic), 20 (myopic) | 0.18 logRAD (emmetropic), 0.24 logRAD (hyperopic), 0.12 logRAD (myopic) binocular | Not available | CS significantly reduced in all groups | Not reported |
McDonald et al18 | Conductive keratoplasty | 6 months | 143 | 0.18 logMAR or better in 77% (monocular) | Not available | 76% reported very satisfied/satisfied | Not reported |
Menassa et al19 | Intrastromal femtosecond Ring incision | 18 months | 25 | 0.2 logMAR (monocular) | Not available | Corneal steepening 0.90 D | ▸ 36% reported rings around light sources |
Limnopoulou et al20 | Flexivue microlens inlay | 1 year | 47 | 0.14 logMAR (monocular), 0.13 logMAR (binocular) | Not available | ▸ HOA increased. ▸ CS decreased. ▸ 81.25% reported ▸ UCNVA excellent | No surgical complications |
Garza et al21 | The raindrop Inlay | 1 year | 20 | <0.1 logMAR (monocular and binocular) | Not available | ▸ Photopic CS no significant change. ▸ 95% reported satisfied or very satisfied UCNVA, UCIVA. ▸ 100% satisfied or very satisfied UCDVA | ▸ 1 patient reported severe haloes at 6 months, ▸ 10% inlays removed because dissatisfaction, decentration. |
Seyeddain et al22 | The Kamra inlay | 2 years prospective | 24 | 0.1 logMAR (monocular) | Not available | 0.1 logMAR UCIVA | ▸ 1 eye with epithelial ingrowth in the pocket ▸ 1eye with epithelial iron deposit |
Baily et al23 | The Icolens corneal inlay | 1 year | 52 | 0.4 logMAR (monocular) | Not available | 90% reported happy with the procedure | 11 inlay explanted because minimal improvement UCNVA |
Hipsley (ASCRS 2011) | The LaserACE procedure | 18 months | 134 | 0.18 logMAR or better in 89% | Not available | ▸ 1.25–1.75 D increase in objective accommodation. ▸ 0.18 logMAR or better in 95% UCIVA | No major complications |
Berrow (2014)62 | PresVIEW scleral implant | 3 months (ongoing 2 years FDA clinical trial) | 28 | Not available | 0.3 logMAR 100% (monocular, binocular) | Mean lines of improvement at near 2.3 monocular and 2.0 binocular | Not reported |
Note: some visual acuities were converted to logMAR using the visual acuity conversion chart prepared by Jack T Holland.
BDCNVA, best distance corrected near visual acuity; CLE, clear lens extraction; CS, contrast sensitivity; FDA, Food and Drug Administration; HOA, high order aberration; LogMAR, log minimum angle of resolution; logRAD, logarithm of the reading acuity determination; UCDVA, uncorrected distance visual acuity; UCIVA, uncorrected intermediate visual acuity; UCNVA, uncorrected near visual acuity.