Table 1

Parameters from swept-source optical coherence tomography-measured anterior chamber angle sections before and after argon laser peripheral iridoplasty (ALPI)

Pre-ALPI*1 day post-ALPI†3 months post-ALPI†
Superior AOD5000.0510.105 (0.003)0.083 (0.015)
Superionasal AOD5000.0570.120 (0.001)0.088 (0.044)
Nasal AOD5000.1350.179 (0.002)0.160 (0.012)
Inferonasal AOD5000.0940.184 (0.005)0.148 (0.001)
Inferior AOD5000.0590.101 (0.025)0.088 (0.054)
Inferotemporal AOD5000.0940.157 (0.004)0.150 (0.011)
Temporal AOD5000.0990.149 (0.003)0.161 (0.009)
Superotemporal AOD5000.0650.103 (0.031)0.096 (0.006)
Superior AOD7500.1050.118 (0.062)0.167 (0.011)
Superionasal AOD7500.0930.145 (0.004)0.123 (0.046)
Nasal AOD7500.1910.212 (0.059)0.264 (0.025)
Inferonasal AOD7500.1890.257 (0.007)0.199 (0.05)
Inferior AOD7500.1080.208 (0.022)0.142 (0.063)
Inferotemporal AOD7500.1870.203 (0.036)0.234 (0.021)
Temporal AOD7500.1490.209 (0.004)0.183 (0.044)
Superotemporal AOD7500.0500.108 (0.006)0.119 (0.003)
  • *Mean measurements are shown.

  • †Mean measurements at the indicated time point and paired t-test p values of significance (in brackets) when comparing mean angle measurement at the indicated time point with the pre-ALPI measurement. AOD, angle opening distance.