The pattern electroretinogram in retinal and optic nerve disease

A quantitative comparison of the pattern of visual dysfunction

  • Published:
Documenta Ophthalmologica Aims and scope Submit manuscript

Abstract

A retrospective analysis was performed on the transient and steady-state pattern electroretinograms recorded from 42 patients with glaucoma, 13 patients with senile dementia of the Alzheimer's type, 58 patients with diabetes mellitus, and 92 control subjects to evaluate the pattern of electroretinographic changes associated with retinal and optic nerve disease. The amplitudes of both the initial positive component (N1 to P1) and the subsequent negative component (P1 to N2) of the transient (4 rps) responses were measured. From these measurements the (P1 to N2)/(N1 to P1) was derived. The N1 to P1 amplitude of the steady-state pattern electroretinogram also was measured. In the glaucoma patients all three amplitude measures, as well as the amplitude ratio of the components of the transient response, were reduced significantly compared with age-matched controls (p < 0.05). A similar pattern was detected in the patients with Alzheimer's disease, but in this case the only statistically significant amplitude reduction was in the steady-state pattern electroretinogram. A different pattern was observed among the diabetic patients (both with and without retinopathy). Only minor reductions in the amplitude of the transient pattern electroretinogram, which were not statistically significant, were noted. In addition, the ratio of the amplitudes of the components of the transient response did not differ from age-matched controls. The amplitude of the steady-state pattern electroretinogram was reduced in diabetics, but this was significant only for those patients with retinopathy (p < 0.01). These findings support the suggestion that an analysis of both the positive and negative components of the pattern electroretinogram may be useful for differentiating the contributions of retinal and optic nerve dysfunction to visual impairment. The results also indicate that in both retinal and optic nerve disease the steady-state pattern electroretinogram can be an earlier sign of dysfunction than the transient pattern electroretinogram.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Riggs LA, Johnson EP, Schick AML. Electrical responses of the human eye to moving stimulus pattern. Science 1964; 144: 567–68.

    Google Scholar 

  2. Lawwill T. The bar pattern electroretinogram for clinical evaluation of the central retina. Am J Ophthalmol 1974; 78: 22–48.

    Google Scholar 

  3. Trick GL, Wintermeyer DH. Spatial and temporal frequency tuning of pattern reversal retinal potentials. Invest Ophthalmol Vis Sci 1982; 23: 774–79.

    Google Scholar 

  4. Vaegan, Arden GG, Hogg CR. Properties of normal electroretinograms evoked by patterned stimuli in man. Doc Ophthalmol Proc Ser 1982; 31: 111–29.

    Google Scholar 

  5. Trick GL. Retinal potentials in patients with primary open angle glaucoma: physiological evidence for temporal frequency tuning deficits. Invest Ophthalmol Vis Sci 1985; 26: 1750–58.

    Google Scholar 

  6. Trick GL, Bickler-Bluth M, Cooper DG, Kolker AE, Nesher R. Pattern reversal electroretinogram (PRERG) abnormalities in ocular hypertension. Curr Eye Res 1988; 7: 201–7.

    Google Scholar 

  7. Berninger TA, Arden GB. The pattern electroretinogram. Eye 1988; 2 (suppl): 257–83.

    Google Scholar 

  8. Harrison JM, O'Connor PS, Young SL, Kincaid M, Bently R. The pattern ERG in man following surgical resection of the optic nerve. Invest Ophthalmol Vis Sci 1987; 28: 492–99.

    Google Scholar 

  9. Sherman J. Simultaneous pattern reversal electroretinograms and visual evoked potentials in diseases of the macula and optic nerve. Ann NY Acad Sci 1982; 388: 214–26.

    Google Scholar 

  10. Arden GB, Vaegan, Hogg CR. Clinical and experimental evidence that the pattern electroretinogram (PERG) is generated in more proximal retinal layers than the focal electroretinogram. Ann NY Acad Sci 1982; 388: 580–607.

    Google Scholar 

  11. Dawson WW, Stratton Rd, Hope GM, et al. Tissue responses of the monkey retina: tuning and dependence on inner layer integrity. Invest Ophthalmol Vis Sci 1986; 18: 988–91.

    Google Scholar 

  12. Holder GE. Significance of abnormal pattern electroretinography in anterior visual pathway dysfunction. Br J Ophthalmol 1987; 71: 2166–71.

    Google Scholar 

  13. Holder GE. Pattern electroretinography in patients with delayed pattern visual evoked potentials due to distal anterior visual pathway dysfunction. J Neurol Neurosurg Psychiatry 1989; 52: 1364–68.

    Google Scholar 

  14. Trick GL, Barris MC, Bickler-Bluth M. Abnormal pattern electroretinograms in patients with senile dementia of the Alzheimer type. Ann Neurol 1989; 26: 226–31.

    Google Scholar 

  15. Diabetic Retinopathy Study Research Group. Diabetic retinopathy study, report no. 7: Modification of the airlie house classification of diabetic retinopathy. Invest Ophthalmol Vis Sci 1981; 21: 210–26.

    Google Scholar 

  16. Trick GL, Burde RM, Gordon MO, Kilo C, Santiago JV. Retinocortical conduction time in diabetes with abnormal pattern reversal electroretinogram and visual evoked potentials. Doc Ophthalmol 1988; 70: 19–28.

    Google Scholar 

  17. Trick GL. Pattern reversal retinal potentials in ocular hypertensives at high and low risk of developing glaucoma. Doc Ophthalmol 1987; 65: 79–85.

    Google Scholar 

  18. Dawson WW, Trick GL, Litzkow C. An improved electrode for electroretinography. Invest Ophthalmol Vis Sci 1979; 9: 988–91.

    Google Scholar 

  19. Weinstein GW, Arden GB, Hitchings RA, Ryan S, Calthorpe CM, Odum V. The pattern electroretinogram (PERG) in ocular hypertension and glaucoma. Arch Ophthalmol 1988; 106: 923–28.

    Google Scholar 

  20. Wanger P, Persson HE. Pattern reversal electroretinograms in unilateral glaucoma. Invest Ophthalmol Vis Sci 1983; 24: 749–53.

    Google Scholar 

  21. Bach M, Hiss P, Rover J. Check size specific changes of the pattern electroretinogram in patients with early open-angle glaucoma. Doc Ophthalmol 1988; 69: 315–22.

    Google Scholar 

  22. Prager TC, Garcia CA, Mincher CA, Mishra J, Chu H-H. The pattern electroretinogram in diabetes. Am J Ophthalmol 1990; 109; 279–84.

    Google Scholar 

  23. Arden GB, Hamilton AMP, Wilson-Holt J, Ryan S, Yudkin JS, Kurtz A. Pattern electroretinograms become abnormal when background diabetic retinopathy deteriorates to a preproliferative stage: possible use as a screening test. Br J Ophthalmol 1986; 70: 330–35.

    Google Scholar 

  24. Coupland SG. A comparison of oscillatory potential and pattern electroretinogram measures in diabetic retinopathy. Doc Ophthalmol 1987; 66: 207–18.

    Google Scholar 

  25. Wanger P, Persson HE. Early diagnosis of retinal changes in diabetes: a comparison between electroretinography and retinal biomicroscopy. Acta Ophthalmol 1985; 63: 716–20.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nesher, R., Trick, G.L. The pattern electroretinogram in retinal and optic nerve disease. Doc Ophthalmol 77, 225–235 (1991). https://doi.org/10.1007/BF00161370

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00161370

Key words

Navigation