Microdensitometer system for microradiography

  • Published:
Histochemie Aims and scope Submit manuscript

Summary

A microdensitometer system for point measurements in areas down to a few square micrometers is described. The detector system is connected to an integrating digital voltmeter, constituting a very sensitive system. The digital output signals and a digital identification are registered on a recorder and on a tape punch, thus facilitating computer analysis.

The precision of the equipment varied from ∼1.1 per cent, for low signal levels, to ∼0.3 percent for the highest signal levels. Stray light, the only important source of systematic errors, was found to influence the output signal level. Concerning determinations of the densities, however, a variation of the order of 1 per cent was only obtained for small areas with densities differing from that of the background.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Caspersson, T.: Quantitative ultramikrospektrographische Verfahren. Mikrochim. Acta 1, 1–26 (1956).

    Google Scholar 

  • Einarson, L., E. Hansen u. H. G. Krüger: Das elektrische Leitz-Mikroskop-Photometer MPE und seine Anwendung in der Cytophotometrie. Leitz Mitt. Wiss. u. Tech. 3, 129–134 (1965).

    Google Scholar 

  • Grampp, W., and O. Hallén: Microphotometry in X-ray contact microscopy. Exp. Cell Res. 19, 83–92 (1960).

    Google Scholar 

  • Hansen, G.: Energetische Grenzen der Mikro-Spektralphotometrie. Zeiss-Mitt. 2, 117–124 (1981).

    Google Scholar 

  • Lindström, B.: Roentgen absorption spectrophotometry in quantitative cytochemistry. Acta radiol. (Stockh.), Suppl. 125 (1955).

  • —, and B. Philipson: Densitometric evaluation at quantitative microradiography. Histochemie 17, 194–200 (1969).

    Google Scholar 

  • Naora, H.: Microspectrophotometry in visible light range. In: Handbuch der Histochemie, hrsg. von W. Graumann und K. Neumann, Bd. I/1, S. 192–219. Stuttgart: Fischer 1958.

    Google Scholar 

  • Philipson, B., and B. Lindström: Specimen preparation for quantitative microradiography. Histochemie 17, 201–206 (1969).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lindström, B., Philipson, B. Microdensitometer system for microradiography. Histochemie 17, 187–193 (1969). https://doi.org/10.1007/BF00309862

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00309862

Keywords

Navigation