Automatic perimetry in glaucoma visual field screening

A clinical study

  • Published:
Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie Aims and scope Submit manuscript

Summary

Automatic computerized perimetry was compared to careful manual selective perimetry (a variant of that proposed by Armaly) in 181 eyes of 100 patients from a glaucoma open-care unit. The results of the two methods were very similar. Thus all defects found were identified by the automatic perimeter, and one pathologic field was missed by the manual selective perimetry. The automatic examination gave 16% false positive results and the manual 11% when optimally performed. The false positives could be greatly reduced (to 4.4% and 3.3% respectively) by rescreening. In a comparison with “routine” perimetry, the automatic screening is shown to be superior.

Zusammenfassung

Automatische computergesteuerte Perimetrie wurde mit sorgfältiger manueller selektiver Perimetrie (einer Variante der von Armaly vorgeschlagenen), verglichen. 181 Augen von 100 Patienten einer Glaukom-Poliklinik wurden untersucht. Die Ergebnisse beider Methoden waren sehr ähnlich. Alle gefundenen Defekte wurden durch die automatische Perimetrie entdeckt, ein pathologisches Gesichtsfeld dagegen wurde bei der manuellen selektiven Perimetrie nicht gefunden. Die automatische Prüfung ergab in 16 % falsche Resultate, die manuelle, unter optimalen Bedingungen, 11 %. Die falschen positiven Resultate konnten durch erneutes Screening-Verfahren deutlich reduziert werden (auf 4.4 % bzw. 3.3 %). Verglichen mit der „Routine”-Perimetrie hat sich das automatische Screening-Verfahren als die bei weitem vorteilhaftere Alternative erwiesen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Armaly, M.F.: Selective perimetry for glaucomatous defects in ocular hypertension. Arch. Ophthal. 87, 518–524 (1972)

    Google Scholar 

  • Aulhorn, E.: Glaukom-Gesichtsfeld. Ophthalmologica 158, 469–487 (1969)

    Google Scholar 

  • Aulhorn, E., Harms, H.: Early visual field defects in glaucoma. In: Glaucoma, Symposium Tutzing Castle 1966, pp 151–186. Basel-New York: Karger 1967

    Google Scholar 

  • Chaplin, G.B.B., Edwards, J.H., Gedye, J.L., Marlows, S.: Automated system for testing visual fields. Proc. IEE 120, 1321–1327 (1973)

    Google Scholar 

  • Drance, S.M., Wheeler, C., Pattullo, M.: The use of static perimetry in the early detection of glaucoma. Canad. J. Ophthal. 2, 249–258 (1967)

    Google Scholar 

  • Fankhauser, F.: Kinetische Perimetrie. Ophthalmologica 158, 406–418 (1969)

    Google Scholar 

  • Grignolo, A., Tagliasco, V., Zingirian, M.: Preliminary results about a new remotely controlled projection campimeter. Ophthalmologica 171, 432–438 (1975)

    Google Scholar 

  • Heijl, A., Krakau, C.E.T.: An automatic static perimeter. Design and pilot study. Acta ophthal. (Kbh) 53, 293–310 (1975a)

    Google Scholar 

  • Heiji, A., Krakau, C.E.T.: An automatic perimeter for glaucoma visual field screening and control. Construction and clinical cases. Albrecht v. Graefes Arch. klin. exp. Ophthal. 197, 13–23 (1975b)

    Google Scholar 

  • Krieglstein, G.K., Andrae, K.: The screening of the central visual field. Albrecht v. Graefes Arch. klin. exp. Ophthal. 193, 145–152 (1975)

    Google Scholar 

  • Pashley, J.C.: Trial with new automatic central field test. L'Année Thér. et Clin. en Ophthal. 25, 348–354 (1974)

    Google Scholar 

  • Rock, W.J., Drance, S.M., Morgan, R.W.: Visual field screening in glaucoma. (An evaluation of the Armaly technique for screening glaucomatous visual fields). Arch. Ophthal. 89, 287–290 (1973)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Heijl, A. Automatic perimetry in glaucoma visual field screening. Albrecht v. Graefes Arch. klin. exp. Ophthal. 200, 21–37 (1976). https://doi.org/10.1007/BF00411430

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00411430

Keywords

Navigation