Measurement of contrast sensitivity function using pattern-reversal visual evoked responses

  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract

In order to determine whether pattern-reversal visual evoked response (VER) can be used to measure contrast sensitivity function (CSF), we investigated the effect of change of contrast upon pattern-reversal VER. Contrast thresholds for VER were extrapolated in five spatial frequencies. The CSF curve obtained from the VER showed the inverted U-shape as the psychophysical CSF curve. However, the low frequency fall-off that is usually seen in psychophysical CSF was less evident in the electrophysiological CSF. The difference between the electrophysiological CSF and the psychophysical CSF increased along with the spatial frequency. Proper stimulus conditions would make this method of evaluation of CSF by pattern reversal VER useful in relatively young children in whom psychophysical tests cannot be performed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Arden GB (1978) The importance of measuring contrast sensitivity in cases of visual disturbance. Br J Ophthalmol 62: 198–209

    Google Scholar 

  • Atkinson J, Braddick O, French J (1979) Contrast sensitivity of the human neonate measured by the visual evoked potential. Invest Ophthalmol Vis Sci 18: 210–213

    Google Scholar 

  • Campbell FW, Kulikowski JJ (1972) The visual evoked potential as a function of contrast of a grating pattern. J Physiol (Lond) 222: 345–356

    Google Scholar 

  • Campbell FW, Robson JG (1968) Application of Fourier analysis to the visibility of gratings. J Physiol 197: 551–556

    Google Scholar 

  • Coupland SG, Kirkham TH, Evans G (1982) Electrophysiological determination of contrast sensitivity function in the clinical setting. In: Niemeyer G, Huber CH (eds) Techniques in Clinical Electrophysiology of Vision. Proceedings of the 19th I.S.C.E.V. Symposium, Horgen-Zurich, 1981. Documenta Ophthalmologica Proceedings Series, Vol 31. The Hague, Dr W Junk, 1982, pp 361–370

  • Dobson JS, Davison PA (1980) A new rapid test of contrast sensitivity function utilizing spatial bandwidth equalization. Invest Ophthalmol Vis Sci 19: 213–221

    Google Scholar 

  • Essock EA, Lehmkuhle S (1982) The oblique effects of pattern and flicker sensitivity: implications for mixed physiological input. Perception 11: 441–455

    Google Scholar 

  • Fiorentini A, Pirchio M, Spinelli D (1980) Scotopic contrast sensitivity in infants evaluated by evoked potentials. Invest Ophthalmol Vis Sci 19: 950–955

    Google Scholar 

  • Hirsch J, Puklin JE (1983) Reduced contrast sensitivity may precede clinically observable retinopathy in Type 1 diabetes. Proceedings of the XXIII International Ophthalmological Congress in San Francisco, California, Philadelphia, Lippincott pp 719–724

  • Katsumi O, Matsuhashi M, Oguchi Y (1980) Effect of stimulus parameters on the pattern reversal VECP. Acta Soc Ophthalmol Jpn 84: 1723–1730

    Google Scholar 

  • Kawara T, Obazawa H (1980) Development of MTF measuring apparatus. Jpn J Clin Ophthalmol 33: 1505–1509

    Google Scholar 

  • Kayazawa F, Yamamoto T, Itoi M (1981) Clinical measurement of contrast sensitivity function using laser generated sinusoidal grating. Jpn J Ophthalmol 25: 229–236

    Google Scholar 

  • Kelly DH (1971) Theory of flicker and transient responses. II. Counterphase gratings. J Opt Soc Am 61: 632–640

    Google Scholar 

  • Lennerstrand G, Lundh B (1980) Improvement of contrast sensitivity from treatment for amblyopia. Acta Ophthalmol 58: 292–294

    Google Scholar 

  • Levi DM, Harwerth RS (1980) Contrast sensitivity in amblyopia due to stimulus deprivation. Br J Ophthalmol 64: 15–20

    Google Scholar 

  • Mainster MA, Timberlake GT, Schepens CL (1981) Automated variable contrast acuity testing. Ophthalmology 88: 1045–1053

    Google Scholar 

  • Seiple HS, Kupersmith MJ, Nelson JI, Carr RE (1984) The assessment of evoked potential contrast threshold using real-time retrieval. Invest Ophthalmol Vis Sci 25: 627–631

    Google Scholar 

  • Skalka HW (1980) Comparison of Snellen acuity, VER acuity, and Arden grating scores in macular and optic nerve disease. Br J Ophthalmol 64: 24–29

    Google Scholar 

  • Sokol S, Dobson V (1976) Pattern reversal visually evoked potential. Invest Ophthalmol Vis Sci 15: 58–60

    Google Scholar 

  • Sokol S, Domar A, Moskowitz A (1980) Utility of the Arden grating test in glaucoma screening: high false-positive rate in normals over 50 years of age. Invest Ophthalmol Vis Sci 19: 1529–1533

    Google Scholar 

  • Spekreijse H (1966) Analysis of EEG response in man evoked by sine wave modulated light. Dr JW Junk Publishers, The Hague, pp 129–140

    Google Scholar 

  • Sugimachi Y (1979) MTF and VEP by laser interference fringes, and its clinical use in ophthalmology. Proc XVI Symp of Internat Soc Clin Electrophysiol of Vision. Morioka, 1978 (Ed) Tazawa Y pp 241–248

  • Weatherhead RG (1980) Use of the Arden grating test for screening. Br J Ophthalmol 64: 591–596

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This study was supported in part by the Massachusetts Lions Eye Research Fund

Rights and permissions

Reprints and permissions

About this article

Cite this article

Katsumi, O., Tanino, T. & Hirose, T. Measurement of contrast sensitivity function using pattern-reversal visual evoked responses. Graefe's Arch Clin Exp Ophthalmol 223, 190–195 (1985). https://doi.org/10.1007/BF02174058

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02174058

Keywords

Navigation